  1. Go to the settings panel of the Sigur access point object, which is created on the basis of the Sigur server object in the Hardware tab of the System settings dialog box window.
    Image Added
  2. In the ID field (1), enter the access point number on the Sigur server.

    Info
    titleNote

    The Configuration field (2) displays the access point configuration, which is set using the switch on the card of the corresponding Sigur ACS controller.

  3. From the Type of access Access point type drop-down list (3), select the type of access point managed by the controller:
    • Barrier;
    • Door;
    • Gate;
    • NFC terminal;
    • Turnstile.
  4. From the Entrance drop-down list (4), select the Region object corresponding to the area on the side of exit from the access point.
  5. From the Exit drop-down list (5), select the Region object corresponding to the area on the side of entrance to the access point.
  6. Set the access control parameters at entrance and exit (6):
    1. From the Entrance and Exit drop-down lists, select the decision-making side for granting access:

      1. Axxon PSIM Software decides - access decision is automatically made by ACFA PSIM.
      2. Operator decides - access access decision is made by the operator.

        Info
        titleNote.
        To process the request operator is to create a by an operator, you must create an Event Manager interface object and configure it for the Operator’s query (Access granted) event. For more information about this object and its functions, please refer to Guide for configuring and working with the Event Manager integration module.
    2. Set the Don’t wait access cycle for entry and Don’t wait access cycle for exit checkboxes if it is necessary to record the passage access immediately after placing after placing the access card to the reader. If the passage access is considered to be performed only after passing the access point (i.e. door sensor is triggered), unset clear this checkbox.
  7. Click the Apply button to save all the changes (7).

The Sigur ACS access points are now configured.