Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

In order to manage an OnGuard reader, go to the Map window and open the functional You can manage the OnGuard Reader in the Map window using the function menu of the relevant  OnGuard Reader object by right-clicking its icon.

Image RemovedImage Added

The commands of the functional function menu are described in the table.

Command

Description

Open Door

Open the door controlled by the reader

Set mode: Locked

Lock the reader

Set mode: Card only

Allow access by card only

Set mode: Pin or Card

Allow access by PIN

-

code or card

Set mode: Facility Only

Allow access by facility code match

Set mode: Unlock

Unlock the reader

Set mode: Pin and Card

Allow access by PIN

-

code and card

Set mode: Facility Only

Allow access by facility code match

Get Hardware statusGet the status of the hardware

Open Door

Open the door controlled by the reader

Set mode: Default

Set the default reader mode


Info
titleNote