Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Common name

Integrated hardware (name of devices)

Functionality

Name in price list

Information on manufacturer

Type of integration

Hardware connection interface

ACFA PSIM version
POLON ALPHA


Polon4500
Polon4900
TSR
ROP
EKS
EWK
SAL
UCS
Monitoring, controlAxxon PSIM Alarm Service (Polon), per panelPolon-Alfa Spółka
z ograniczoną odpowiedzialnością Sp.k.
Website: http://www.polon-alfa.pl/en
low-level protocolRS-2321.1
SatelIntegra 32 / Integra 64 / Integra 64 + / Integra 128+ / Integra 256+Monitoring, configuration, controlAxxon PSIM Intruder Alarm System (Satel), per panelSATEL
Website: http://www.satel.pl/
low-level protocolRS-2321.1
UniPOS

IFS 7xxx where x is the version

Monitoring, configuration, control

Axxon PSIM Alarm Service (UniPOS Conventional Series), per line

Axxon PSIM Alarm Service (UniPOS Addressable Series), per panel

UniPOS

Website: http://unipos-bg.com/

low-level protocolRS-2321.1
Siemens Cerberus ECO

FC1840-A3
FDT181
FDO181
FDCI181-2
FDCIO181-2
FDCL181

Monitoring, controlAxxon PSIM Alarm Service (Siemens Cerberus ECO), per panel

Siemens

Website: https://www.siemens.com/global/en/home.html

low-level protocolRS-2321.1
DSCDSC PC-1864Monitoring, controlAxxon PSIM Alarm Service (DSC), per panel

3301 Langstaff Road
Concord, Ontario, Canada

Website: http://www.dsc.com/

low-level protocolRS-2321.1
Texecom

Premier Elite 12-W\12-W LINE
Premier Elite 24\24-W
Premier Elite 48\48-W
Premier Elite 88
Premier Elite 168
Premier Elite 640

Monitoring, controlAxxon PSIM Alarm Service (Texecom Premier Elite), per control panel

Texecom
Website: https://www.texe.com/

low-level protocolEthernet, RS-2321.1

RISCO

ProSYS™ Plus Main PanelMonitoring, controlAxxon PSIM Fire Alarm Control Panel Risco ProSys, per panel

RISCO LTD
Israel, 75655 Rishon LeZion, 14 Hachoma Street
Phone: +972-3-9637777
Fax: +972-3-9616584
Email: info@riscogroup.com
Sales department: sales@riscogroup.com
Website: https://www.riscogroup.com/

Low-level protocolEthernet1.1

RISCO Panel

All models of the ProSYS™ Plus Main Board seriesMonitoring, controlAxxon PSIM Fire and Security Alarm System AxACFA Sensor License, each zone is licensed as a sensor.

RISCO LTD
Israel, 75655 Rishon LeZion, 14 Hachoma Street
Phone: +972-3-9637777
Fax: +972-3-9616584
Email: info@riscogroup.com
Sales department: sales@riscogroup.com
Website: https://www.riscogroup.com

Low-level protocolEthernet1.1
Honeywell Esser

FlexES Control
IQ8Control

Monitoring, control

Axxon PSIM Fire Alarm Control Panel ESSER by Honeywell, per panel

Esser by Honeywell
Website: https://www.esser-systems.com/en/index/

SDKRS232 to Essernet network by SEI module1.1
Cerberus PROCerberus PRO series panelMonitoring, controlAxxon PSIM Fire Alarm Control Panel Siemens Cerberus PRO, per panel

Siemens
Website: https://www.siemens.com/global/en/home.html

BACnet protocolTCP/IP to the control panel or SAFEDLINK subnetwork, requires at least "S3" license in control panel1.1
Senstar The Network Managers (NM)MonitoringThe Network Managers (NM), per controller

Senstar

Website: https://senstar.com

SDKEthernet1.1
RozetatechRozetatech OBELISK-1.0 Gateway Monitoring, controlAxxon PSIM Fire and Security Alarm System 50 AxACFA Sensor License, per 50 sensorsRozetatech Co Ltd
B-1710, 2nd Woollim Lions Valley.14, Sagimakgol-ro 45beon-gil, 
Jungwon-gu, Seongnam-si, Gyeonggi-do
Phone: +82-31-736-5308 
Website: http://www.rozetatech.co.kr
Email: contactus@rozetatech.co.kr

SOFT-SOFT

(AxACFA)

-1.1

...

NameFunctionality in Axxon PSIMName in price listUniversal protocol

MOXA cards (list of all cards which can be connected by the Moxa MX-AOPC UA Server or via SNMP is presented here).

Note. Licensing of OPC and SNMP connection differs. For OPC, the connection with the OPC Server is license-protected, while each Moxa input and output is licensed for SNMP.

Connection with OPC Wrapper:

  • control relay depending on type of card;
  • receive the current state of connected sensors.
Axxon PSIM OPC Wrapper module, per OPC computerOPC

Connection with SNMP Wrapper:

  • receive the current state of connected sensors.
Axxon PSIM SNMP Wrapper module, per channelSNMP
Bosch FPA 1200/5000 and MAP-5000, as well as UGM2020, UEZ2000, Allegiant, VCS. etc. panels as part of a BIS subsystem. The ability to use the OPC Wrapper for for other models should must be checked with the manufacturer.
  • monitoring, control.
Axxon PSIM OPC Wrapper module, per OPC computerOPC
FSA SIEMENS Cerberus-PRO
  • receive the current state of object;
  • reset the object in its default state;
  • arm/include the object in the controlled area;
  • disarm/exclude the object from the controlled area;
  •  set the object in Test mode;
  • set the object in active state from quiet;
  • set the object in quiet state from active.
Axxon PSIM OPC Wrapper module, per OPC computerOPC
ACS Gallagher 6000
  • receive events about passes;
  • door tampering;
  • exit by button.
Axxon PSIM OPC Wrapper module, per OPC computerOPC
Schrack Seconet (OPC server by TIGER-SOFT http://www.tiger-soft.com.pl)
  • monitoring of the status of a zone or an element;
  • sending control commands to a group or an element;
  • internal acoustic off command;
  • external acoustic off command;
  • summary alarm reset command.
Axxon PSIM OPC Wrapper module, per OPC computerOPC
Honeywell Esser (OPC server by TIGER-SOFT http://www.tiger-soft.com.pl)

Monitoring:

  • status of a point or a zone;
  • status of an output;
  • status of a line;
  • status of a panel;
  • status of an acoustic signaling device;
  • status of an UE.

Control:

  • connect/disconnect a point or a zone;
  • connect/disconnect an output;
  • send a command to a panel.
Axxon PSIM OPC Wrapper module, per OPC computerOPC
Sterownik FSG
  • open/close of fire dumper;
  • set the angle of fire dumper;
  • receive the current state of connected devices;
  • receive states of fire dumper (open, close, damage);
  • control program which control all fire dumpers in case of damage;
  • show temperatures inside the ventilation tunnels;
  • control smoke exhaust fan.
Axxon PSIM BACnet Wrapper Module, per deviceBACnet
AVTECH - Room Alert 24E- Alarm Switch

Monitoring of the following events:

  • Humidity is out-of-bounds;
  • Humidity is within borders;
  • Cabinet open;
  • Cabinet close;
  • Temp is out-of-bounds;
  • Temp is within bounds;

  • Power loss;

  • Power connected.
Axxon PSIM SNMP Wrapper module, per channelSNMP
NAG SNR-ERD
  • receiving status and events from controller elements, for example, temperature sensors, relay status (on, off)
Axxon PSIM SNMP Wrapper module, per channelSNMP
TFortis
  • device status poll
Axxon PSIM SNMP Wrapper module, per channelSNMP
Bostex Door Access System
  • door status monitoring;
  • door control.
Axxon PSIM OPC Wrapper module, per OPC computerOPC
Teletek IRIS Addressable Fire Alarm Panel (vendor: Teletek Electronics)Getting information on detection tool states, inputs/outputs, the panel itself, zones, and control commandsAxxon PSIM Modbus Wrapper module, per IP deviceModbus
KSPA 9030-01 automatic fire fighting systems controller (vendor: PJSC «Gazprom avtomatizatsiya»)Getting information on detection tool statesAxxon PSIM Modbus Wrapper module, per IP deviceModbus

KZ fire fighting controller (vendor: OOO «Vega-GAZ»)

Getting information on detection tool states, inputs/outputs, and control commandsAxxon PSIM Modbus Wrapper module, per IP deviceModbus
Schrack Seconet fire alarm stations (vendor: Schrack Seconet AG) Getting information on detection tool statesAxxon PSIM Modbus Wrapper module, per IP deviceModbus
OptaSense perimeter intrusion detection system (vendor: OptaSense Ltd)Getting information on detection tool statesAxxon PSIM Modbus Wrapper module, per IP deviceModbus

...