  • Out of RAM.
  • Camera is connected, but does not send data.
  • No events from a detection tool.
  • Archive doesn't work.
  • The frame rate is 0 when recording to the archive.
  • No video is recorded on events from a detection tool.
  • Any internal errors of Axxon One.
  • Out of system disk space.

The self-diagnostics service has the following rules for cleaning the system disk:

Free memory remainingCleanup mechanism
< 20 GBAll server logs, including the archived logs, are deleted from the system disk
< 15 GBAll events older than one week are deleted
< 10 GBAll events older than one day are deleted
< 5 GBAll events older than one hour are deleted
< 3 GBAll events are deleted