You can select and configure cameras for displaying in the Monitor interface window window in two ways:
To select video cameras individually on the settings panel of the Monitor object, do the following:
If multistream mode is enabled for the camera, in the Video stream drop-down list, select the number of the video stream that you want to display on the Monitor
. If no stream is selected, the default stream is used.
Info | ||
---|---|---|
| ||
Configuration of the Server video streams is described in Configuration of multistream video. The selected video stream is requested when receiving a video signal both from the Server and via the Videogate. |
If a video signal needs to be decimated for its transmission to the Client Monitor, select the required frame rate of the video signal from the drop-down list in the fps column.
Note | ||
---|---|---|
|
We strongly discourage you from setting additional decimation and/or compression |
for video signals displayed on the Server Monitor, as |
this results in unnecessary consumption of the Server resources |
while the video image quality deteriorates. |
Features of fps selection:
If video signal compression level needs to be changed for transmission to the Client Monitor, select the required level of video signal compression from the drop-down list in
the Compression column. The compression level of the video signal increases from 0 (no compression) to 5 (maximum compression).
Info | ||
---|---|---|
| ||
If you change the compression level for the Client, the video signal on the Server will be pre-decompressed, which will result in a great load increase on the CPU of the Server. |
To change the algorithm of the video signal compression for transmission to the Client Monitor, select the required algorithm of compression from the Compressor drop-down list. If the compressor is selected, the value in the Compression list is must be selected as well.
Info | ||
---|---|---|
| ||
Recompression of the video signal is performed on the Videogate side. |
If a video archive from the selected camera must be transmitted to the Monitor from the Backup archive object, select the name of this object from the drop-down list in the Backup archive column.
Info | ||
---|---|---|
| ||
In case the access to the Backup archive is performed through the Videogate, the specified value must coincide with the selected value for this video camera when configuring the Videogate |
object—see Selecting and configuring the cameras for the Videogate module. |
If there is a fisheye or a panomorph lens on the camera (see Configuring fisheye cameras), in the Display type drop-down list, select the type of displaying video from the camera in the Surveillance window: virtual telemetry or panorama.
Info | ||
---|---|---|
| ||
Conversion is enabled in the Video surveillance monitor when zooming |
in (see Mouse PTZ control) or in the function menu of the Surveillance window ( |
see Enabling fisheye). |
This feature won't work if:
Video cameras on the settings panel of the Monitor object are now selected.