Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Select the created Axxon One Monitor in the tree (1), and in the Monitor drop-down list (2), select the monitor number in the computer's operating system where the Axxon One Monitor window will be displayed.
  2. If necessary, adjust the window position of the Axxon One Monitor on the screen using one of the following methods (3):
    1. Set the coordinates and dimensions manually:
      FieldDescriptionValue
      XHorizontal offset from the left border of the video imageThe coordinates of the upper left corner of the interface window, which are expressed as a percentage relative to the horizontal and vertical dimensions of the screen, respectively
      YVertical offset from the top border of the video image
      WInterface window widthThe dimensions of the interface window, which are expressed as a percentage relative to the horizontal and vertical dimensions of the screen, respectively
      HInterface window height
    2. Using a test window:
      1. Click the X button.
      2. Position the Set dimensions test window where the Axxon One Monitor window should appear.
      3. Click OK. The fields X, Y, W, H will be updated to reflect the position and size of the test window.
  3. In the table on the Camera list List of cameras tab (4), select Axxon One cameras for display using one of the following methods:
    1. Click All (5) to select all available cameras, which will then appear in the table.
    2. Select individual cameras by selecting them sequentially from the drop-down lists by number or name (6).
      Info
      titleNote

      To move down a row in a table, use the down arrow key ↓ on your keyboard. To delete a row, click on it and press Ctrl+Del.

  4. Go to the Basic settings tab and set the Main monitor checkbox if you want the Axxon One Monitor to display the control panel from Axxon One:
  5. There can be only one Main monitor: if you set this checkbox for a certain Axxon One Monitor object, this option will be unavailable for other Axxon One Monitor objects.
    Info
    titleNote

    If you set the checkbox while the AxxonOne.exe process is already running (i.e., the Axxon One Monitor is displayed), you will need to restart the AxxonOne.exe process for the changes to take effect. This can be done by restarting the Axxon PSIM, for example.

  6. Click Apply.

...