Go to documentation repository
Page History
The BioSmart 4 controller network parameters are configured on the Network configuration tab on the settings panel of the BioSmart 4 object.
- In the Controller IP field (1), enter the IP address of the BioSmart 4 controller.
- In the Controller port field (2), enter the controller port number. The default number is 20002.
In the Mask (3) and Gateway (4) fields and Gateway fields, enter the addresses of the network mask and gateway, respectively.
Select the Identification mode from the drop-down list (5):Local—working mode of the BioSmart 4 controller, when identification and storage of templates take place on the device itself;
Server—working mode, when palm templates are stored on the external BioSmart biometric identification Server and not in the controller local memory. In this mode, the biometric data is compared on the external server, which allows expanding the number of palm templates in the database and increasing the identification speed- In the Host IP field (1), enter the IP address of the BioSmart biometric identification Server.
- In the Host port field (2), enter the port of the BioSmart biometric identification Server.
Click the Apply . button to save the changes
.
When selecting this mode, it is necessary to set the following parameters of the external BioSmart biometric identification Server:The BioSmart 4 controller network parameters are configured.
Overview
Content Tools