- Go to the Wiegand 0 or Wiegand 1 tab.
- From the Direction drop-down list, select the direction of information transfer via the Wiegand interface:
- Wiegand Out—used to transfer information to external devices.
- Wiegand In—used to receive information from external devices.
- Not used—the Wiegand interface isn’t used to transfer information (default). If you select this value, further configuration isn’t relevant.
- From the Wiegand mode drop-down list, select the operation mode of the Wiegand interface: Wiegand 26, Wiegand 32, Wiegand 34, Wiegand 37, Wiegand 40, Wiegand 42, Wiegand 48, Wiegand 64.
- From the Data type drop-down list, select the type of the transferred data: Card ID—transfer of the RFID card code (default) or Employee ID—transfer of the employee code (ID).
- From the Pulse width, µs drop-down list and Sending interval, µs drop-down list, select the values of the data transfer parameters via the Wiagand interface. Default values: Pulse width, μs—200 μs, Sending interval, µs—2000 μs.
- Click the Apply button to save the changes.
Сonfiguring of the BioSmart Quasar terminal is complete.