- From the Input drop-down list (4), select the input to which the access sensor is connected: Aboard input, Input #1 RCU, Input #2 RCU, Input #3 RCU, Input #4 RCU. If the access sensor isn’t connected, select the No value. In this case, further configuration isn’t relevant.
- From the Active state drop-down list (5), select Low level or High level of the signal that appears on the discrete input, at which the access sensor triggering is detected.
- From the Relay locking drop-down list (6), select the relay locking mode when the access sensor triggering is detected. On door opening—the relay is disabled when the access sensor is triggered. On door closing—the relay is disabled when the access sensor returns to its initial state.
If it is necessary to consider the an access event, select the the On value from the Consider access event drop-down list (7). The default value is Off.
- If it is necessary to consider a door hack, select the On value from the Consider door hack drop-down list (8). The default value is Off.
- Click the Apply button to save the changes.