Go to documentation repository
Page History
...
- Run the Log Management Utility (see Starting the utility).
- Go to the Logging levels tab.
- In the AxxonOne Client field, select the required Client logging level from the drop-down list. The default value is Info. Logging levels are described in the table.
- In the AxxonOne Server field, select the required server logging level from the drop-down list. The default value is Info. Logging levels are described in the table.
Logging level
Level of event detail
Logging level description
None
No
Event logging disabled
Error
Low
Only system errors are logged
Warning
Low
Only system warnings and system errors are logged
Info
Low
Informational messages, system warnings, and system errors are logged
Debug
Medium
Debug events, informational messages, system warnings, and system errors are logged
Trace
High
All system events are logged
Info title Note - If you change the Server logging level, it will be restarted (see Launching Starting and closing stopping Axxon One software).
- If you installed Axxon One in the Failover server and client mode (see Installation), the Client and Supervisor logging levels are selected (see Configuring Failover VMS).
- Click the OK button.
...
Overview
Content Tools