Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Go to the settings panel of the Monitor interface object.
  2. In the List of cameras tab, click the Range button.

    As a result, the Add/Edit Camera Objects window opens.
  3. Select the required cameras in the left list of the Add/Edit Camera Objects window.
  4. Move the selected cameras to the right list by clicking the button.

    Info
    titleNote

    The right list is the list of cameras selected for displaying in the Monitor window.
    The button is used for inverse action, i.e. that is, for moving the selected video cameras from the right list to the left one.

    In both lists, you can change the sorting by clicking the column names to make it easier to find the required cameras and their settings.

    As a result, the selected cameras will be are displayed in the list on the right of the Add/Edit Camera Objects window.
  5. If it is necessary, select the names of required cameras in the right list for bulk editing of their parameters.

    Note
    titleAttention!
    The same parameters will be set for all selected cameras.
  6. In the fps drop-down list, select the required frame rate of a video signal to enable decimation of a video signal for transmitting to the Monitor of the Clientclient.

    Note
    titleAttention!

    We strongly discourage you from setting additional decimation and/or compression for video signals displayed on the Server server Monitor, as this results in unnecessary consumption of the Server server resources while the video image quality deteriorates.

    Info
    titleNote
    The selected fps value must be less than the frame rate of the video signal digitized by the video capture device. Otherwise, the frame rate of the video signal will be is equal to the frame rate of the digitization.
    All settings described below belong to the Common data for elements selected on the right group.
    For correct decimation of a video stream compressed with the help of H.264 or MPEG4 codecs, the fps value must be equal to the keyframe rate specified in the device (IP camera) or or Axxon PSIM settings (see Configuring video compression).
  7. If the video compression level must be changed for transmitting to the Monitor of the Clientclient, select the required level of video signal compression from the the Compression drop-down list. Compression The compression level is increased from 0 (no compression) to 5 (maximum compression).

    Info
    titleNote

    If the compression level is set for the Clientclient, a video signal on the Server server must be decompressed beforehand, which leads to a significant increase in the load on the Server server CPU.

  8. If the Monitor must receive live and archive video from the selected cameras via the Gate object, then select the name of this object from the Gate drop-down list.
  9. To enable smart search in the archive of the selected cameras, select the VMDA metadata storage object corresponding to the VMDA tracks database for smart search from the VMDA metadata storage drop-down list.
  10. From the Hardware accelerated decoding drop-down list, select Do no not change (default value, hardware acceleration specified for each camera is used), CPU decoder (blank value), Nvidia decoder, or Intel Quick Sync. Selecting a hardware decoder increases the load on the corresponding CPU.
  11. If necessary, select the required macro from the Macro1 and Macro2 drop-down lists (the default value is Do not change). Later you can run these macros from the camera menu in the Surveillance window (see Running macros from the Surveillance window)
  12. If a video archive from the selected camera must be transmitted to the Monitor from the Backup archive object, then select the name of this object from the Backup archive drop-down list.
  13. If the transmission from the Backup archive object is performed via the Gate object, then select the name of this object from the Gateway for backup archive drop-down list.
  14. If cameras are used to view video archive from external storage, set the Setup edge storage checkbox. As a result, for each selected camera, the external storage available to it will be applied.
  15. By default, the Monitor receives a video stream through the Serverserver. If it is necessary to get the video stream not through a Server, server but from cameras directly, from the the Connection drop-down list, select Direct.
  16. To save the specified parameters, click the Set for cameras selected on the right button.
    As a result, the specified parameters will be displayed in the list on the right of the Add/Edit Camera Objects window.
  17. Repeat steps 5-15 for bulk editing of all required cameras.
  18. To save the changes and close the Add/Edit Camera Objects window, click the Apply changes and close button.
  19. Specified camera settings will be displayed in the List table on the settings panel of the Monitor object.
  20. To save the changes, click the Apply button.

...