- Go to the Devices tab.
- Select the Output object in the object tree. If necessary, you can change the values of the parameters that are listed in the table:
Parameter Value Description Other Enable Yes By default, the output is disabled. To enable it, select Yes No Name Output If necessary, enter the output name Input/output ID 0 (non-editable field) Normal status Open From the drop-down list, select the status of the output in which it must be when there is no alarm Closed Camera Camera 1.Camera From the drop-down list, select the camera with which you want to bind the output. As a result, the output becomes a child of the selected camera
Info title Note - If the output is a child of the Channel object, then:
- When you enable the output, the Channel parent object is automatically enabled.
- When you enable all Input and Output child objects, the Channel parent object is also enabled.
- If the output is a child of the Channel object, then:
- Click the Apply button.
As a result, the output is switched to the specified operating mode.
To check the operation of the output, click the Test button. If the output is configured correctly, its status will briefly change.