Go to documentation repository
The values of the param_id and param_value parameters, required for the SET_IPINT_PARAM reaction, can be individual both for each of integrated IP cameras and for their firmwares.
The valuesof the param_id and param_value are defined as follows:
Using any word processor, open a file in this directory with the Ipint.<Name of camera driver>.rep name, for example, Ipint.SonyIpela.rep.
Info | ||
---|---|---|
| ||
In most cases, the name of the driver is the same as the name of the manufacturer of the IP device. Contact AxxonSoft support to check the name of the driver for the required manufacturer. |
In this example the param_id="daynight" parameter can be used to switch the Day/Night mode on the camera. In this case the possible values of the param_value parameter are: auto, on, off, timer or sensor.
Info | ||
---|---|---|
| ||
Example of using the SET_IPINT_PARAM reaction:
As a result of reactions execution the value of the “daynight” parameter is “on” for Camera 1. |
To enable the SET_IPINT_PARAM reaction, the multistream mode must be enabled in Axxon PSIM (see Configuring the multistream video). Keep in mind that if only one stream is integrated for the camera, then there will be no video in the multistream mode.
You can find out the number of integrated streams in the list of IP devices integrated with Axxon PSIM (see Documentation Drivers Pack).
If this way can’t be used for any reason, then find out the number of integrated streams as follows: