The following types of events are stored in the Axxon One system log:
Event type | Description |
---|---|
Debug info | Debug events provide detailed information about the execution of various processes in the system |
Info | Info events capture important but non-critical events that are useful for general understanding of system operation and monitoring of system status |
Alarm | Alarm events indicate potentially problematic situations that require user's attention |
Error | Errors indicate malfunctions or problems in system operation |
Audit | User's actions in the system |
...
The table below shows examples of events for different objects in the system that are included in the system log:
Object | Event |
---|---|
Archive | File or partition of archive is corrupted |
File or partition of archive is restored | |
File or partition of archive in suboptimal state. It is still usable but may be not fully operable until the background maintenance job is finished | |
Archive partition error | |
User added comment | |
Macro | Macro activated |
Macro deactivated | |
Unable to execute macro | |
Macro not found | |
Camera | Started recording to archive from camera |
Finished recording to archive from camera | |
Serial number does not match the one specified in settings | |
IP device. Signal restored | |
Camera armed | |
Camera armed in private mode by user | |
Camera disarmed | |
IP device connected | |
IP device disconnected | |
Camera. Archive. Export started | |
Camera. Archive. Export impossible | |
Camera. Archive. Export finished | |
PTZ device. Move to preset is impossible. The reason: required preset number is not found on IP device | |
PTZ device. Move to preset number | |
PTZ device. Manual move | |
Camera. User added comment | |
Camera. An object recognized from list | |
Failed to apply settings | |
Authorization failed | |
Internal error | |
Network failure | |
Reboot | |
Camera (alarm) | Alarm initiated by user |
Alarm initiated by automatic rule on camera, detection {name of the detector} | |
Alarm initiated by macro | |
Alarm being processed | |
User cannot process alarm. Reason: alarm being processed by another user. Alarm status {status} | |
Alarm processed by user with resolution {resolution} | |
Alarm pending | |
Alarm needs processing | |
Detector | Automatic rule activated |
Automatic rule cannot be executed: executing device unavailable or malfunctioning | |
Automatic rule deactivated | |
Detection triggered | |
Specified detection triggered | |
Beginning of detection triggering | |
End of detection triggering | |
Alarm status change: alarm is processed by user {user} with resolution {resolution}, user comment {comment} | |
LP recognized from list | |
Specified detection triggered, LP {recognized license plate} | |
Detection triggered, LP {recognized license plate} | |
Detection triggered. Age. Gender | |
Detection specified triggered. Age. Gender. Temperature—{temperature value} {temperature unit} | |
Detection triggered. Age. Gender. Temperature—{temperature value} {temperature unit} | |
Detection triggered. Max Temperature {maximum temperature} {temperature unit}. Min Temperature {minimum temperature} {temperature unit}. Avg Temperature {average temperature} {temperature unit} | |
Face recognized from list | |
Face recognized from list. Age. Gender | |
Detection triggered, queue (min.: {value}, max.: {value}) | |
Visitor passage in direction of "Entrance" | |
Visitor passage in direction of "Exit" | |
Detection triggered. Tamper type | |
System | System integrity check passed successfully |
System integrity compromised | |
Bookmarks | Error editing bookmark |
Error adding bookmark | |
Bookmark added | |
Bookmark changed | |
Bookmark exported | |
Bookmark removed | |
Protection enabled | |
Protection disabled |