Video stream and scene requirements for the Person-based privacy masking |
To configure the Person-based privacy masking detector, do the following:
- Go to the Detection Tools
- Detectors tab.
- Below the required camera, click Create… → Category: Poses → Person-based privacy masking.
By default, the detection tool detector is enabled and set to mask a person's head.
If necessary, you can change the detection tool detector parameters. The list of parameters is given in the table:
Parameter | Value | Description | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Object features | ||||||||||||||||||||||||
Record mask to archive | Yes | By default, the recording of the mask to the archive is disabledenabled. To record mask to the archive (see Displaying information from a detector (mask)), select the Yes valuedisable, select the No value | ||||||||||||||||||||||
No | ||||||||||||||||||||||||
Video stream | Main stream | If the camera supports multistreaming, select the stream for which detection is needed. Selecting a low-quality video stream allows reducing the load on the Serverserver | ||||||||||||||||||||||
Second stream | ||||||||||||||||||||||||
Other | ||||||||||||||||||||||||
Enable | Yes | The detection tool detector is enabled by default. To disable the detection tool, select the No value value | ||||||||||||||||||||||
No | ||||||||||||||||||||||||
Name | Person-based privacy masking | Enter the detection tool detector name or leave the default name | ||||||||||||||||||||||
Decoder mode | Auto | Select a processing resource for decoding video streams. When you select a GPU, a stand-alone graphics card takes priority (when decoding with NVIDIA NVDEC chips). If there is no appropriate GPU, the decoding will use the Intel Quick Sync Video technology. Otherwise, CPU resources will be are used for decoding | ||||||||||||||||||||||
CPU | ||||||||||||||||||||||||
GPU | ||||||||||||||||||||||||
HuaweiNPU | ||||||||||||||||||||||||
Number of frames processed per second | 1 | Specify the number of frames that the detection tool detector will process per second. The value must be in the range range [0.016; 100] | ||||||||||||||||||||||
Type | Person-based privacy masking | Name of the detection tool detector type (non-editable field) | ||||||||||||||||||||||
Advanced settings | ||||||||||||||||||||||||
Number of measurements in a row to trigger detection | 3 | Specify the minimum number of frames on which the detection tool detector must detect objects to generate an event. The value must be in the range [1, 20] | ||||||||||||||||||||||
Segmenting network file | Select Specify a neural network file. The standard neural networks for different processor types are located in the C:\Program Files\Common Files\AxxonSoft\DetectorPack\NeuroSDK directory. You don't need to select the standard neural networks in this field, the system will automatically select the required one. If you use a custom neural network, specify the path to the file.
| |||||||||||||||||||||||
Basic settings | ||||||||||||||||||||||||
Detection mode | CPU | Select the | neural network mode (see detector operation mode (see Hardware requirements for neural analytics operation, Selecting Nvidia GPU when configuring detectors).
| other
| will carry the
| However
| will
| be
| detection tool
| with
| 3
| |||||||||||||
Nvidia GPU 0 | ||||||||||||||||||||||||
Nvidia GPU 1 | ||||||||||||||||||||||||
Nvidia GPU 2 | ||||||||||||||||||||||||
Nvidia GPU 3 | ||||||||||||||||||||||||
Intel GPU | ||||||||||||||||||||||||
Intel HDDL NCS (not supported) | ||||||||||||||||||||||||
Intel Multi-GPU | ||||||||||||||||||||||||
Intel GPU 0 | ||||||||||||||||||||||||
Intel GPU 1 | ||||||||||||||||||||||||
Intel GPU 2 | ||||||||||||||||||||||||
Intel GPU 3 | ||||||||||||||||||||||||
Intel HDDL NCS (not supported) | ||||||||||||||||||||||||
Mask | ||||||||||||||||||||||||
Body | Yes | By default, the detection tool detector masks only a person's head. To mask other parts of the body, select the Yes value for the corresponding parameters | ||||||||||||||||||||||
No | ||||||||||||||||||||||||
Feet | Yes | |||||||||||||||||||||||
No | ||||||||||||||||||||||||
Forearms | Yes | |||||||||||||||||||||||
No | ||||||||||||||||||||||||
Hands | Yes | |||||||||||||||||||||||
No | ||||||||||||||||||||||||
Head | Yes | |||||||||||||||||||||||
No | ||||||||||||||||||||||||
Hips | Yes | |||||||||||||||||||||||
No | ||||||||||||||||||||||||
Shins | Yes | |||||||||||||||||||||||
No | ||||||||||||||||||||||||
Shoulders | Yes | |||||||||||||||||||||||
No |
By default, the entire frame is a detection area.
To save the parameters of the detection tooldetector, click the the Apply button. To cancel the changes, click the Cancel button.
Configuring the Person-based privacy masking is complete.
Selected body parts of all persons will be are hidden in the frame. For a user group with limited permissions to view masked video (see Roles), the mask is displayed on the video image of the selected camera in the Detection Tools and Detectors and Hardware sections, on the layouts, in the archive, and when exporting. For the admin user group, the mask is displayed only on the video image of the selected camera in the Detection Tools Detectors and Hardware sections, and when exporting, if the View masked video checkbox is clear (see Standard video recordings export).