Go to documentation repository
Page History
...
To configure the Fire detector, do the following:
- Go to the Detection Tools tab Detectors tab.
- Below the required camera, click Create… → Category: Production Safety → Fire detector.
...
If necessary, you can change the detector parameters. The list of parameters is given in the table:
Parameter | Value | Description | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Object features | |||||||||||||||
Record mask to archive | Yes | By default, the sensitivity scale of the detector is recorded to the archive (see Displaying information from a detector (mask)). To disable the parameter, select the No value | |||||||||||||
No | |||||||||||||||
Video stream | Main stream | If the camera supports multistreaming, select the stream for which detection is needed. Selecting a low-quality video stream reduces the load on the Serverserver | |||||||||||||
Other | |||||||||||||||
Enable | Yes | The detector is enabled by default. To disable the detector, select the No value | |||||||||||||
No | |||||||||||||||
Name | Fire detector | Enter the detector name or leave the default name | |||||||||||||
Decoder mode | Auto | Select a processing resource for decoding video streams. When you select a GPU, a stand-alone graphics card takes priority (when decoding with NVIDIA NVDEC chips). If there is no appropriate GPU, the decoding will use the Intel Quick Sync Video technology. Otherwise, CPU resources will be are used for decoding | |||||||||||||
CPU | |||||||||||||||
GPU | |||||||||||||||
HuaweiNPU | |||||||||||||||
Number of frames processed per second | 0.1 | Specify the number of frames that the detector will process per second. The value must be in the range [0.016; , 100] | |||||||||||||
Type | Fire detector | Name of the detector type (non-editable field) | |||||||||||||
Advanced settings | |||||||||||||||
Neural network file | Select a neural network file. The standard neural networks for different processor types are located in the C:\Program Files\Common Files\AxxonSoft\DetectorPack\NeuroSDK directory. You don't need to select the standard neural networks in this field, the system will automatically select the required one. If you use a custom neural network, enter a path to the file.
| ||||||||||||||
Ignore black and white image | Yes | The parameter is disabled by default. If you don't want the detector to generate an event when the image is black and white, select the Yes value | |||||||||||||
No | |||||||||||||||
Number of measurements in a row to trigger detection | 5 | Specify the minimum number of frames with fire for in which the detector must detect fire to generate an event. The value must be in the range [5; , 20] | |||||||||||||
Scanning mode | Yes | The parameter is disabled by default. You can use the scanning mode (see Configuring the scanning mode) to detect small objects or or objects in areas far away from the camera (see Configuring the scanning mode). For this, select the Yes value. This mode doesn’t provide absolute detection accuracy , but can improve detection performance | |||||||||||||
No | |||||||||||||||
Basic settings | |||||||||||||||
Mode | CPU | Select a processor for the neural network operation (seeHardware requirements for neural analytics operation, Selecting Nvidia GPU when configuring detectors).
| other
| will carry the
| will
| be
| |||||||||
Nvidia GPU 0 | |||||||||||||||
Nvidia GPU 1 | |||||||||||||||
Nvidia GPU 2 | |||||||||||||||
Nvidia GPU 3 | |||||||||||||||
Intel GPU | |||||||||||||||
Intel NCS (not supported) | |||||||||||||||
Intel Multi-GPU | |||||||||||||||
Intel GPU 0 | |||||||||||||||
Intel GPU 1 | |||||||||||||||
Intel GPU 2 | |||||||||||||||
Intel GPU 3 | |||||||||||||||
Intel HDDL (not supported) | |||||||||||||||
Huawei NPU | |||||||||||||||
Sensitivity | 33 | Specify the sensitivity of the detector empirically. The value must be in the range [1 , 99]. The default value is 33. The preview window displays the sensitivity scale of the detector that relates to the sensitivity parameter. If the scale is green, fire isn't detected. If the scale is yellow, fire is detected, but not enough to generate an event. If the scale is red, fire is detected, and the detector generates an event if the scale is red through the sampling period (50 seconds by default).
|
By default, the entire frame is the detection area. In the preview window, you can specify the detection areas using the anchor points Configuring a detection area):
(see- Right-click in the preview window.
- If you want to specify the detection area by one or more rectangles, select Detection area (rectangle). If you specify a rectangular area, the detector will analyze only this area. The rest of the frame will be is ignored.
- If you want to specify the detection area by one or more polygons, select Detection area (polygon). If you specify one or several polygonal areas, the detector will analyze the entire frame. The part of the frame not included in the specified polygons will be is blacked out.
Note title Attention! You must select the detection area (polygon or rectangle) experimentally. For some neural networks, the quality of detection will be better with rectangle, for others—with a polygon.
Info | ||
---|---|---|
| ||
|
To save the parameters of the detector, click the Apply button. To cancel the changes, click the Cancel button.
Configuring the Fire detector is complete.