Go to documentation repository
The Web-server object is used for video surveillance via a web browser and the TCP/IP communication environment. The settings panel of the Web-server object and its description are shown in the figures and tables given below.
The Basic settings tab:
...
№ | Parameter | Method of setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | Identification number* | Automatically | Displays the identification number of the Web-server object in the digital video surveillance system with the distributed architecture | Sequence of numbers | -NA | From 1 and above.to 2147483647 Depends on the number of the Web-server objects in the digital video the video surveillance system with the distributed architecture |
2 | Name* | Enter the value into in the field | Sets the name of the Web-server object in the digital video surveillance system with the distributed architecture | Latin, Cyrillic, and service characters | Web-server | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | Disable | Set the checkbox | Sets the state (enabled or disabled) of the Disables the Web-server object in the digital video surveillance system with the distributed architecture | Boolean type | Clear | Set—the Web-server object is disabled and isn't used Clear—the Web-server object is enabled and used |
4 | Computer | Select the value from the list | Sets the Computer parent object of the digital system with the distributed architecture , to which the given Web-server object belongs | Name of the Computer objects registered in the system | Name of the Computer parent object | Depends on the number of the Computer objects in the digital video surveillance system with the distributed architecture |
The HTTP-server group | ||||||
5 | Port number | Enter the value into the in the field | Sets the number of the port used by the HTTP - server (used for video surveillance via a web browser, including via the internet) | Sequence of numbers | 80 | Any valid unused port numbers. The number of ports is determined by the system administrator. |
Number of connections | Enter the value into in the field | Sets the maximum possible number of connections to the Server server via the Web-server module. Each request to view the video signal from each camera and each request to control all PTZ devices regadless , regardless of their number, is considered as a connection | Sequence of numbers | 100 | Any integer. If you specify the 0 value is specified in the the Video surveillance monitor of the Web-server module, video signals wonaren't be displayed | |
Parallel exports | Enter the value into in the field | Sets the maximum allowed number of archive files to be uploaded simultaneously | Sequence of numbers | 2 | From 1 and above. If you leave the field blank, the lowest possible value is used | |
The HTTPS-server group | ||||||
6 | Use HTTPS protocol | Set the checkbox | Enables the HTTPS protocol when transmitting data via the Web-server | Boolean type | Clear | Set—Set—the HTTPS protocol is used Clear—Clear—the HTTPS protocol isn't used |
Key | Enter the value into in the field | Key Sets the path to the folder of the key for data transmission via the HTTPS protocol | Latin, Cyrillic, and service characters | C:\Program Files (x86)\Axxon PSIM\Modules\SSL\ssl_internal.key | Depends on the location of data encryption key when transmitting data via the HTTPS protocol | |
Certificate | Enter the value into the in the field | Certificate Sets the path to the folder of the certificate for data transmission via the HTTPS protocol | Latin, Cyrillic, and service characters | C:\Program Files (x86)\Axxon PSIM\Modules\SSL\ssl_internal.cert | Depends on the location of certificate file when transmitting data via the HTTPS protocol | |
Port number | Enter the value into in the field | Sets the number of the port used for the HTTPS - server (used for video surveillance in a web browser and in via the internet) | Sequence of numbers | 443 | Any available unused port numbers. The number of ports is specified by the system administrator | |
Not in a group | ||||||
7 | Default user | Select the value from the list | Sets the user with rights and authority to conduct the video surveillance from the Remote workstation using the Web-server module | Names of the users registered in the system and added to the rights | Not definedNA | Depends on the number of the users registered in Axxon PSIM |
8 | ECHD translation | Set the checkbox | Enables to the use the http of HTTP requests used for integration with ECHD | Boolean type | Clear | Set—requests used for integration with ECHD are run for the Camera objects on the basis of which the ECHD channel objects are created Clear—requests used for integration with ECHD are not aren't run |
9 | Use NAT address | Set the checkbox | Enables the router address substitution in the ECHD requests | Boolean type | Clear | Set—when Set—when requesting the URL of streams via the HTTP API, the IP address of the router specified in the settings panel of the RTSP-Server RTSP server object is substituted in the response to the request Clear—when requesting the URL of streams via the HTTP API, the IP address of the Server server in its local network is returned in response to the request |
...
№ | Parameter | Method of setting the parameter value | Parameter description | Representation | Default value | Value range |
10 | Range | Click the button | Opens the window for bulk selection of cameras (see Bulk selecting and configuring cameras for the Web-server)- | NA | -NA- | NA |
11 | Clear | Click the button | Clears the list of the added cameras- | NA | -NA- | NA |
12 | Add all | Click the button | Adds to the list of cameras all Camera objects created in the system- | NA | -NA- | NA |
13 | Number | Select the value from the list | Sets the number of the camera the video from which is transmitted to the remote workstation using the Web-server module | Identifiers of the Camera objects registered in the systemNot defined | NA | Depends on the number of the cameras in the digital video surveillance system with the distributed architecture |
Camera | Select the value from the list | Sets the name of the camera the video from which is transmitted to the remote workstation using the Web-server module | Names of the Camera objects registered in the systemNot defined | NA | Depends on the number of the cameras in the digital video surveillance system with the distributed architecture | |
Video stream | Select the value from the list | Sets the number of the video stream used for displaying in the Web-server interface | Numbers of video streams enabled on the camera and the By default value | By default | Depends on the number of the enabled streams on of the camera | |
Live video | Select the value from the list | Sets the source of live video that is displayed in the Web-server interface | Available means to get live video | Serverserver | Server—live video is received from the Server server to which the camera is connected Videogate—live video is received from the Videogate Note. If a camera is not isn't configured to transmit video through the Videogate, then this item is unavailable in the list | |
Archive | Select the value from the list | Sets the source of the archive video that is displayed in the Web-server interface | Available means to get archive videoServer | server |
| |
Microphone | Select the value from the list | Sets the name of microphone associated with the camera, the audio from which will be is transmitted through the Web-server | Names of the Microphone objects registered in the systemNot defined | NA | Depends on the number of the Microphone objects in the digital video surveillance system with the distributed architecture | |
Speaker | Select the value from the list | Sets the name of the speaker associated with the camera, which will be is used to playback play back the audio received from the client | Names of the Speaker objects registered in the systemNot defined | NA | Depends on the number of the Speaker objects in the digital video surveillance system with the distributed architecture | |
Compression | Select the value from the list | Sets the compression level of the video signal transmitted to the remote workstations using the Web-server module. Increasing the level of compression leads to deterioration of the video signal quality | Reference compression levelsNot defined | NA | Not defined, 1 – —5. Value The 1 value corresponds to the minimum compression level, the 5—to the maximum compression level. If the compression level is not isn't specified, video signal is transmitted with the same compression level as set for recording and transmitting video | |
Control | Select the value from the list | Sets the camera control (arm/disarm, PTZ, recording to the archive) according to the user rights | Boolean type | Enabled | Enabled—camera control according to the user rights is enabled Disabled—camera control is disabled regardless of the user rights | |
14 | PTZ control | Select the value from the list | Set Sets the prioritiy priority of the PTZ control during video surveillance using a web browser | Names of the PTZ control priorities | Low priority |
|
The RTSP settings tab:
№ | Parameter | Method of setting the parameter value | Parameter description | Representation | Default value | Value range | |
15 | RTSP - server | Set the checkbox | Sets the RTSP server (one or several) to process the ECHD requests | Names of the RTSP - server objects registered in the system | Not defined | NA | Set—RTSP server is Set—RTSP Server will be used to process ECHD requests Clear—RTSP Server wonClear—RTSP server isn't be used to process ECHD requests |
...