Go to documentation repository
...
The settings panel of the Failover service object is shown in the figure.
Table
The table describes the setting parameters corresponding to the elements of the settings panel of the Failover service object.
№
| Parameter
| Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | Identification number* | Automatically | Displays the identification number of the Failover service object | Numbers, letters, periods, hyphen, dash, and underscore | NA | Depends on the number of the Failover service object in the video surveillance system with distributed architecture |
2 | Name* | Enter the value in the field | Sets the name of the Failover service object in the video surveillance system with distributed architecture | Latin, Cyrillic, numbers, and service characters | Failover service | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | Disable | Set the checkbox | Disables the Failover service object in the video surveillance system with distributed architecture | Boolean type | Clear | Set—the Failover service object is disabled and isn't used Clear—the Failover service object is enabled and used |
4 | Monitor PC | Select the value from the list | Sets the name of the |
server, the state of which |
is monitored by the object | Names of the Computer objects registered in the system |
NA | Depends on the number of the Computer objects registered in the system |
5 | Speed of object transfer to monitoring computer (rpm) | Enter the value in the field | Sets the speed of transferring objects if the connection is lost. This setting is necessary so that the failover server sends messages at a certain speed and the receiving server has time to process them. The transfer speed must be set depending on the network speed, server bandwidth, and so on | Sequence of numbers | 1000 | From 0 and above |
6 | Wait for reconnection (s) | Enter the value |
in the field | Sets the time period in seconds after which the configuration will be transferred to the backup |
server after the loss of connection | Sequence of numbers |
NA | From 0 to 65535 |
7 | Time left __ days | Automatically | Displays the period of time in days remaining to restore the configuration from the backup |
server to the main |
server and restore the license | Days | 0.00 | From 0.00 to 50.00 |
8 | Transfer if no ping | Set the checkbox | Specifies if it is necessary to transfer the configuration without the ping from the main monitored |
server | Boolean type | Clear |
Set—the configuration is transferred if there is no ping |
Clear—ping isn' |
t taken into account when transferring the configuration | ||||||
The Objects table |
9 | Type | Select the value from the list | Sets the object type in the configuration of the monitored |
server that |
must be transferred to the backup |
server in case of connection loss | Types of objects registered on the basis of the main |
server |
NA | Depends on the configuration created on the basis of the main |
server |
10 | Number | Select the value from the list | Sets the identifier of the object of the selected type that |
must be transferred to the backup |
server in case of connection loss | Identifiers of the objects of the selected type that are present in the configuration of the monitored |
server |
NA | Depends on the number of the objects of the selected type in the configuration of main |
server |
11 | Name | Automatically | Sets the name of the object that |
must be transferred to the backup |
server in case of connection loss | Names of the objects of the selected type that are present in the configuration of the monitored |
server |
NA | Depends on the configuration created on the basis of the main |
server |
12 | Range | Click the button | Opens the |
window for the complex selection of the monitored objects |
NA | NA |
-
NA |
*Name of the element isn't displayed in the settings panel of the given object.