Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The settings panel of the SIP-operator system object is shown in the figures below.

Image ModifiedTable

The table describes the setting parameters of the SIP-operator system object.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Number 

Enter the value

into

in the field

Sets the

identification

number of the operator to which you can call

Numbers, letters, periods, hyphen, dash, and underscore

-

>=0

NA

A line containing a sequence of any characters (numbers, letters, periods, hyphens, dash, and underscore)

2Bind operator to user rightsSet the checkbox

Enables binding of a SIP-operator to Axxon PSIM user rights. Activates the User drop-down list.

Note. It is used when the User rights are selected by default on the operator's SIP-panel

Set—
Boolean typeClear

Setbinding of a SIP-operator to Axxon PSIM user rights is enabled

Clearbinding of a SIP-operator to Axxon PSIM user rights is disabled

3UserSelect the value from the listSets the user under which it is necessary to register in Axxon PSIM

Name of the User objects registered in the system

NADepends on the number of the User objects in the system
4Device prioritySelect the value from the listSets the priority of a call from this operator in the incoming calls window of the SIP-panelSequence of numbers
No0–10
Clear

From 0 to 10.

  • The lower the number, the higher the priority and, accordingly, the higher the display in the list
.
  • ;
  • If the field is left blank, then the priority is considered to be minimal
.
  • ;
  • Calls from operators with the same priority
will be
  • are sorted by the time of the call

The Server connection tab (only for the SIP-client terminal type).

Image ModifiedTable

The table describes the setting parameters of the Server connection tab.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1LoginEnter the value
into
in the fieldSets the
login
username for connecting to the SIP
-
serverLatin, Cyrillic, and service characters
-
NAA line containing a sequence of any characters (letters, digits, service characters)
2PasswordEnter the value
into
in the fieldSets the password for connecting to the SIP
-
serverLatin, Cyrillic, and service characters
-
NAA line containing a sequence of any characters (letters, digits, service characters

The Address book tab.

Image Modified

Table The table describes the setting parameters of the Address book tab.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

The Address books group
1Address booksSelect the value in the columnSets the list of address books, the numbers of which
will be
are available for this SIP-operator
-
NA
-
NA
-
NA
NumberSelect the value from the listSelects the
address book identifier
identifier of the Address book objectIdentifiers of the Address book objects registered in the system
-
NADepends on the number of the Address book objects in the system
NameSelect the value from the listSelects the name of the
address
 Address book object in Axxon PSIM, the numbers of which are available for this SIP-operatorNames of the Address book objects registered in the system
-
NADepends on the number of the Address book objects in the system
2AllClick the buttonAdds all existing
address books to
 Address book objects to the table
-
NA
-
NA
-
NA
3RangeClick the buttonOpens the Add address books window to add multiple address books
-
NA
-
NA
-
NA