By default, the Program object isn't displayed on the Programming tab. It is designed

...

to create specialized programs in the embedded programming environment of Axxon PSIM. To display the object, specify the OldScript=1 parameter of the HKEY_LOCAL_MACHINE\SOFTWARE\AxxonSoft\PSIM\ registry key (see Registry keys reference guide) or use the tweaki.exe utility by setting the Old scripts support checkbox (see point 19 on the page The Settings panel of the Axxon PSIM section).

The settings panel of the the Program object is shown in the figure.

 

...

The table describes the setting parameters corresponding to the elements of the settings panel of the

...

 Program object.

 

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Program object in the video surveillance system

Numbers, letters, periods, hyphen, dash, and underscore

-

NA

Depends on the number of the Program objects in the digital video surveillance system with distributed architecture

2

Name*

Enter the value

into

in the field

Sets the name of the Program object

Latin, Cyrillic, digits and service characters

Program

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

Disable

Set the checkbox

Sets the state (enabled or disabled) of the Program

Disables the Program object

Boolean type

Clear

Setthe Program object is disabled and isn't used

Clearthe Program object is enabled and used

4

Time schedule

Select the value from the list

Sets the time period during which the given program operates

Names

Name of the Time schedule registered in the system

Never

Neverthis program

will never be

isn't executed

Alwaysthis program is always

in the state of execution

executed

List of the created time schedulesthe program

will be

is executed within

a pre-defined

the time period specified in the time schedule

The Computers group

5

Select an element

Set the checkbox

Sets the computer on which the given program

will be

is executed

Boolean type

Clear

Setthe program

will be

is executed on the specified computer

Clearthe program

will not be

isn't executed on the specified computer

6

Computer

Automatically

Sets the

name of the

computer in the local network

Computer name in the local network

Computer name in the local network

A line containing a sequence of any characters (letters, digits, service characters), case-insensitive.

Number of characters60

7

Name

Automatically

Sets the name of the computer

Name of the Computer object registered in the system

Name of the Computer object registered in the system

A line containing a sequence of any characters (letters, digits, service characters), case-insensitive.

Number of characters60

Not in a

Out of the group

8

Filter

Enter the value

into

in the field

Used

Sets to pre-filter events processed by the program

Latin, Cyrillic, digits, and service characters

, and digits

Not defined

NA

A line containing a sequence of any characters (Latin letters, digits, service characters), case-insensitive.

Number of characters—unlimited.

Filter

The filter format is TYPE|ID|EVENT divided by semicolon. For example, the CAM||MD_STOP;CAM||MD_START

to filter

format filters Alarm and Alarm end events from all Camera objects

9

Text editor

Enter the value

into

in the field

Used to enter

Enters the text of the executed program

that must be executed

Latin, Cyrillic, digits, and service characters

, digits

Not defined

NA

A line containing a sequence of any characters (Latin letters, digits, service characters), case-insensitive.

Number of characters—unlimited

 * Name of the object isn't displayed on the settings panel.