Go to documentation repository
...
№
| Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | Identification number* | Automatically | Displays the identification number of the Display object in the video surveillance system with distributed architecture | Numbers, letters, periods, hyphen, dash, and underscore | NA | Depends on the number of the Display objects in the video surveillance system with distributed architecture |
2 | Name* | Enter the value in the field | Sets the name of the Display object in the video surveillance system with distributed architecture | Latin, Cyrillic, and service characters | Display | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | Disable | Set the checkbox | Displays the Display object in the video surveillance system with distributed architecture | Boolean type | Clear | Set—the Display object is disabled and isn't used Clear—the Display object is enabled and used |
The Computers group | ||||||
4 | Select an element* | Set the checkbox | Contains a list of computers (server, Remote Administrator's workstation, Remote workstation) connected to the given server (Remote Administrator's workstation). The checkboxes corresponding to the computers determine whether or not the computers must display the Monitor objects created on the basis on of the given Display object | Boolean type | Clear | Set—the Monitor object created on the basis of the Display object is displayed in the selected computer Clear—the Monitor object created on the basis of the Display object isn't displayed in the selected computer |
5 | Computer | Automatically | Sets the computer name in the local network | Latin, Cyrillic, numbers, and service characters | Computer name in the local network | Depends on the number of objects in the local network. A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
6 | Name | Automatically | Sets the name to the computer in the video surveillance system with distributed architecture | Latin, Cyrillic, numbers, and service characters | Name of the Computer object registered in the system | Depends on the number of objects in the video surveillance system with distributed architecture A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
The +Activate group | ||||||
7 | Number | Select the value from the list | Sets the number of the Display, the objects of which are displayed on the configured Display at the same time with its objects | Identifiers of the Display type objects registered in the system | NA | Depends on the number of the objects registered in the system |
8 | Name | Automatically | Sets the name of the Display, the objects of which are displayed on the configured Display. It is filled out automatically after you select the Number | Name of the Display object registered in the system | NA | Depends on the number of the objects registered in the system |
...