23

From 0 to 10.

  • The lower the number, the higher the priority and, accordingly, the higher the display in the list;
  • If the field is left blank, then the priority is considered to be minimal;

    Parameter

    Method for setting the parameter value

    Parameter description

    Representation

    Default value

    Value range

    1

    Identification number*

    Automatically

    Displays the identification number of the SIP-operator system object in the video surveillance system with distributed architecture

    Numbers, letters, periods, hyphen, dash, and underscore

    NA

    Depends on the number of the SIP-operator object in the video surveillance system with distributed architecture

    2

    Name*

    Enter the value in the field

    Sets the name of the SIP-operator object in the video surveillance system with distributed architecture

    Latin, Cyrillic, numbers, and service characters

    SIP-operator

    A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

    Number of characters—from 1 to 60

    3

    Disable

    Set the checkbox

    Disables the SIP-operator object in the video surveillance system with distributed architecture

    Boolean typeClear

    Setthe SIP-operator object is disabled and isn't used

    Clearthe SIP-operator object is enabled and used

    4SIP-terminalSelect the value from the listSets the SIP-terminal parent object of the system with distributed architecture to which the given SIP-operator object belongsNames of the SIP-terminal objects registered in the systemName of the SIP-terminal parent objectDepends on the number of the SIP-terminal objects in the system
    5Device prioritySelect the value from the listSets the priority of a call from this operator in the incoming calls window of the SIP-panelSequence of numbersClear

    From 0 to 10.

    • The lower the number, the higher the priority and, accordingly, the higher the display in the list;
    • If the field is left blank, then the priority is considered to be minimal;
    • Calls from operators with the same priority are sorted by the time of the call

    The User group

    6

    Number 

    Enter the value in the field

    Sets the number of the operator to which you can call

    Numbers, letters, periods, hyphen, dash, and underscore

    NA

    A line containing a sequence of any characters (numbers, letters, periods, hyphens, dash, and underscore)

    7Bind operator to user rightsSet the checkbox

    Enables binding of a SIP-operator to Axxon PSIM user rights. Activates the User drop-down list.

    Note. It is used when the User rights are selected by default on the operator's SIP-panel

    Boolean typeClear

    Setbinding of a SIP-operator to Axxon PSIM user rights is enabled

    Clearbinding of a SIP-operator to Axxon PSIM user rights is disabled

    8UserSelect the value from the listSets the user under which it is necessary to register in Axxon PSIM

    Name of the User objects registered in the system

    NADepends on the number of the User objects in the system4Device prioritySelect the value from the listSets the priority of a call from this operator in the incoming calls window of the SIP-panelSequence of numbersClear
  • Calls from operators with the same priority are sorted by the time of the call
  • The Server connection tab (only for the SIP-client terminal type)

    ...

    The table describes the setting parameters of the Server connection tab.

    Parameter

    Method for setting the parameter value

    Parameter description

    Representation

    Default value

    Value range

    1LoginEnter the value in the fieldSets the username for connecting to the SIP serverLatin, Cyrillic, and service charactersNAA line containing a sequence of any characters (letters, digits, service characters)
    2PasswordEnter the value in the fieldSets the password for connecting to the SIP serverLatin, Cyrillic, and service charactersNAA line containing a sequence of any characters (letters, digits, service characters

    The Address book tab

    The table describes the setting parameters of the Address book tab.

     group

    Parameter

    Method for setting the parameter value

    Parameter description

    Representation

    Default value

    Value range

    The Address books
    table
    1Address booksSelect the value in the columnSets the list of address books, the numbers of which are available for this SIP-operatorNANANA
    NumberSelect the value from the listSelects the identifier of the Address book objectIdentifiers of the Address book objects registered in the systemNADepends on the number of the Address book objects in the system
    NameSelect the value from the listSelects the name of the Address book object in Axxon PSIM, the numbers of which are available for this SIP-operatorNames of the Address book objects registered in the systemNADepends on the number of the Address book objects in the system
    2AllClick the buttonAdds all existing Address book objects to the tableNANANA
    3RangeClick the buttonOpens the Add address books window to add multiple address booksNANANA