ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range

The Operators group table

1



NumberSelect the value from the listSelects a SIP-operator identifierIdentifiers of the SIP-operator objects registered in the systemNADepends on the number of the SIP-operator objects in the system
SubscriberSelect the value from the listSelects a SIP-operator numberNumbers of the SIP-operator objects registered in the systemNADepends on the number of the SIP-operator objects in the system
NameSelect the value from the listSelects a SIP-operator name in Axxon PSIMNames of the SIP-operator objects registered in the systemNADepends on the number of the SIP-operator objects in the system

Out of the group

2AllClick the buttonAdds all existing SIP-operators to the tableNANANA
3RangeClick the buttonOpens the Add operators window to add multiple SIP-operatorsNANANA
4DefaultSelect the value from the listSets the default SIP-operatorNASelect on start
  • Select on startwhen you first start the SIP-panel, it is necessary to select the appropriate SIP-operator in the authorization window. Next time, you are logged in under the previously selected SIP-operator;
  • User rightsyou will log into the SIP-panel as the SIP-operator that is linked to the Axxon PSIM user rights. You must also be logged into Axxon PSIM with the corresponding user rights

...