Go to documentation repository
...
The Advanced settings tab:
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | Decompressor | Select the value from the list | Sets the technology using which the compressed video stream is decompressed when displaying the video signal on the monitor Note. By default the parameter is not available for editing. To change the value of this parameter, set the 1 value for the EnableCodecSettings |
registry key ( |
List of available decompressors | No |
|
2 | Compressor | Select the value from the list | Sets the algorithm of the video stream compression Note. By default the parameter is not available for editing. To change the value of this parameter, set the 1 value for the EnableCodecSettings |
registry key ( |
List of available algorithms | No | Depends on the camera model |
3 | Estimate motion | Enter the value in the field | Sets the threshold of the camera sensitivity to motion depending on the change of the object brightness. The delta frame of the video signal is formed according to this criterion | Sequence of numbers | 7 | From 2 to 255 |
4 | Key frames interval | Enter the value in the field | Sets the rate of the key frames | Sequence of numbers | 8 | Depends on the capabilities of the camera |
Out of the group |
31
5 | Additional info |
Enter the value in the field | Sets the |
Note. We recommend setting the Store no less than parameter for no more than 30% of cameras in the system, as this setting is only ADVISORY. If there isn't enough space for the archive recording, the setting is ignored and the recording doesn't stop anyway.
If you create more than 10 cameras in the system, then when attempting to set this parameter for more than 30% of the cameras in the system, after you click the Apply button, a corresponding warning message appears. You can disable it using the NotifyAbout_arch_days registry key (see Registry keys reference guide)
information displayed on the video surveillance monitor above the camera name. This information is added to the export file, and when the frame is printed, to the event log | Line not longer than 100 characters | Blank line | Latin and Cyrillic letters, digits | ||||
6 | Rotation mode | Set the checkbox | Enables the rotation of the video image displayed on the Video surveillance monitor | Boolean type | Clear | Set—rotation is enabled Clear—rotation is disabled | |
7 | Rotate on* | Select the value from the list | Specifies the angle of video image rotation when the rotation mode is enabled | Sequence of numbers | 0 | 0, 90, 180, 270 | |
The Priority group | |||||||
8 | Processing priority | Set the slider in the required position | Sets the priority of the video signals processing by ADC | Order of video signals processing | Normal |
| |
9 | Recording priority | Set the slider in the required position | Set the priority of video signals processing by ADC in the recording mode | Order of video signals processing in the recording mode | Normal |
| |
The Store no less than group | |||||||
10 | Store no less than | Enter the value in the field | Sets the time period for keeping the video archive and audio archive from the camera (in case of synchronous recording) on the server. The parameter allows storing the large archive for the selected camera using the archive of other cameras. Note. We recommend setting the Store no less than parameter for no more than 30% of cameras in the system, as this setting is only ADVISORY. If there isn't enough space for the archive recording, the setting is ignored and the recording doesn't stop anyway. If you create more than 10 cameras in the system, then when attempting to set this parameter for more than 30% of the cameras in the system, after you click the Apply button, a corresponding warning message appears. You can disable it using the NotifyAbout_arch_days registry key (see Registry keys reference guide) | Day or hour, depending on the value selected in the drop-down list | NA | More than 1 | |
11 | Store no less than | Select the value from the list | Sets the units for the time period specified in the Store no less than field | List of available time units | Days | Days Hours | |
The Store no more than group | |||||||
12 | Store no more than | Enter the value in the field | Sets the time period for storing the camera archive, after which the camera archive must be deleted Note. The archive can be deleted before the specified time if it is required for loop recording | Day or hour, depending on the value selected in the drop-down list | NA | More than 1 | |
13 | Store no more than | Select the value from the list | Sets the units for the time period specified in the Store no more than field | List of available time units | Days | Days Hours | |
The Fisheye group | |||||||
14 |
Day or hour, depending on the value selected in the drop-down list
NA
More than 1
Days
Hours
Sets the time period for storing the camera archive, after which the camera archive must be deleted
Note. The archive can be deleted before the specified time if it is required for loop recording
Days
Hours
Out of the group
36
Type
Select the value from the list
Sets the type of the used camera.
This setting affects the set of icons used to display a camera on the map
List of available camera types
NA
37
Processing priority
Set the slider in the required position
Sets the priority of the video signals processing by ADC
Order of video signals processing
Normal
38
Recording priority
Set the slider in the required position
Set the priority of video signals processing by ADC in the recording mode
Order of video signals processing in the recording mode
Normal
39
Rotation mode
Set the checkbox
Enables the rotation of the video image displayed on the Video surveillance monitor
Boolean type
Clear
Set—rotation is enabled
Clear—rotation is disabled
40
Rotate on*
Select the value from the list
Specifies the angle of video image rotation when the rotation mode is enabled
Sequence of numbers
0
0, 90, 180, 270
Lens type | Select the value from the list | Sets the used lens type | Supported lens types | No |
|
15 | Camera position | Select the value from the list | Sets the position of the camera | Supported camera position options | Ceiling |
|
16 | Visible part | Enter the value in the field | Determines which part of the frame is visible on the Video surveillance monitor after the conversion | Percentage | 75% for the Ceiling position 66% for the Wall position Note. The default value may not appear in the field | From 0 to 100 |
The Streams settings tab
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range | |
1 | Streams configuring | Set the checkbox | Enables the video signal multistream option | Boolean type | Clear | Set—video signal multistreaming is enabled; different streams can be used for analytics, archiving, and display Clear—video signal multistreaming is disabled; a single stream is used for analytics, archiving, and display | |
2 | # | Automatically | Sets the number of the stream | Integer | NA | From 1 to 10 | |
3 | Enabled* | Set the checkbox | Sets the used camera streams | Boolean type | Clear | Set—the stream is in use Clear—the stream isn't in use | |
4 | Default | Set the checkbox | Sets the video stream that is used in the following cases:
| List of available streams | Clear | Set—the stream is used by default Clear—the stream isn't used by default
| |
5 | Video analytics | Set the checkbox | Sets the video stream used for video analytics. This stream is used by the standard motion detector, zone detectors, tracking detectors, face detectors (if an external recognizer isn't used). The Video Analytics stream is used for the LPR server, face detectors (if an external recognizer is used), and detectors that are part of the Detector Pack subsystem. You can select the Default stream using the VMDA.ignoreAnaliticStream registry key (see Axxon PSIM base version). The Archive/Archive (alarms) stream is used for the long-term archive | List of available streams | Clear | Set—the stream is used for video analytics Clear—the stream isn't used for video analytics | |
6 | Archive | Set the checkbox | Sets the video stream that is recorded to the archive not upon alarm, but continuously | List of available streams | Clear | Set—the stream is used for archive recording Clear—the stream isn't used for archive recording | |
7 | Archive (alarms) | Set the checkbox | Sets the video stream recorded to the archive upon alarm | List of available streams | Clear | Set—the stream is used for archive recording upon alarm Clear—the stream isn't used for archive recording upon alarm |
...