Go to documentation repository
...
The table describes the setting parameters corresponding to the elements of the settings panel of theFailover service object.
№
| Parameter
| Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | The Identification number* | Automatically | Displays the identification number of the Failover servicesystem object |
Digits, letters, periods, hyphen, dash, and underscore | NA | Depends on the number of the Failover service object in |
the video surveillance system with distributed architecture | ||||
2 | The Name* | Enter the value in the field | Sets the name of the Failover service object in the video surveillance system with distributed architecture | Latin alphabet, Cyrillic, |
digits, and service characters | Failover service | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 | ||||
3 | The Disable | Set the checkbox | Disables the Failover service object in the video surveillance system with distributed architecture | Boolean type | Clear | Set—the Failover service object is disabled and isn't used Clear—the Failover service object is enabled and used |
4 | The Monitor PC | Select the value from the list | Sets the name of the server, the state of which is monitored by the object | Names of the Computer objects registered in the system | NA | Depends on the number of the Computer objects registered in the system |
5 | The Speed of object transfer to monitoring computer (rpm) field | Enter the value in the field | Sets the speed of transferring objects if the connection is lost. This setting is necessary so that the failover server sends messages at a certain speed and the receiving server has time to process them. The transfer speed must be set depending on the network speed, server bandwidth, and so on | Sequence of numbers | 1000 | From 0 and above |
6 | The Wait for reconnection (s) field | Enter the value in the field | Sets the time period in seconds after which the configuration will be transferred to the backup server after the loss of connection with the monitored server | Sequence of numbers | NA | From 0 to 65535 |
7 | The Time left |
0.00 seconds string | Automatically | Displays the period of time in days remaining to restore the configuration from the backup server to the main server and restore the license | Days | 0.00 | From 0.00 to 50.00 |
8 | The Transfer if no ping checkbox | Set the checkbox |
Sets the necessity to transfer the configuration without |
a ping from the main monitored server | Boolean type | Clear | Set—the configuration is transferred if there is no ping Clear—ping isn' |
t taken into account when |
you transfer the configuration |
9 | The Type | Select the value from the list | Sets the object type in the configuration of the monitored server that must be transferred to the backup server in case of connection loss | Types of objects registered on the basis of the main server | NA | Depends on the configuration created on the basis of the main server |
10 | The Number | Select the value from the list | Sets the identifier of the object of the selected type that must be transferred to the backup server in case of connection loss | Identifiers of the objects of the selected type that are present in the configuration of the monitored server | NA | Depends on the number of the objects of the selected type in the configuration of main server |
11 | The Name field | Automatically | Sets the name of the object that must be transferred to the backup server in case of connection loss | Names of the objects of the selected type that are present in the configuration of the monitored server | NA | Depends on the configuration created on the basis of the main server |
12 | The Range | Click the button | Opens the dialog window for the complex selection of the monitored objects | NA | NA | NA |
*Name of the element isn't displayed in the settings panel of the given object.