Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

ParameterMethod for setting the parameter valueParameter description RepresentationDefault valueValue range
1The Identification number*
field
AutomaticallyDisplays the identification number of the ONVIF-Server object in the video surveillance system with distributed architectureNumbersDigits, letters, periods, hyphen, dash, and underscoreNADepends on the number of the ONVIF-Server objects in the video surveillance system with distributed architecture
2The Name*
field
Enter the value in the fieldSets the name of the ONVIF-Server object in the video surveillance system with distributed architectureLatin alphabet, Cyrillic, digits and service charactersONVIF-Server

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3The Disable
checkbox
Set the checkboxDisables the ONVIF-Server object in the video surveillance system with distributed architectureBoolean typeClear

Setthe ONVIF-Server object is disabled and not in use.isn't used

Clearthe ONVIF-Server object is enabled and in use.used

4The Computer
drop-down list
Select the value from the list

Sets the Computer parent object in the system with distributed architecture to which the given ONVIF-Server object belongs

Names of the Computer objects registered in the systemName of the Computer parent objectDepends on the number of the computers in the video surveillance system with distributed architecture
The Basic settings tab
5PortEnter the value in the fieldSets the port number used to connect to the serverInteger numbersNAFrom 1 to 65535
The Connection settings group
56The IP-interface
drop-down list
Select the value from the listSets the network interface (network adapter) used to connect to the serverList of available network interfacesNAThe list of values depends on the network adapters available in the system
76The RTSP-server
drop-down list
Select the value from the listSets the RTSP-serverServer object, the settings of which are applied by the ONVIF-Server object while transmitting the video signal Names of the RTSP-server Server objects registered in the systemNA

Depends on the number of the RTSP-serverServer objects created in Axxon PSIM

8Use Media2 service
Set the checkboxEnables the ONVIF 2.X standard instead of ONVIF 1.XBoolean typeClear

Set—the ONVIF 2.X standard is used. The video is transmitted in the H264, H265, MJPEG, or MPEG4 formats

Clear—the ONVIF 1.X standard is used. The video is transmitted in the MPEG, MJPEG, or H264 formats

9Allow DHCP setting
Set the checkboxEnables the DHCP supportBoolean typeClear

SetDHCP is used

ClearDHCP isn't used

10Discovery modeSet the checkboxEnables the WS-Discovery modeBoolean typeSet

Set—the WS-Discovery mode is enabled

Clear—the WS-Discovery mode is disabled

7The Port
field
Enter the value in the fieldSets the port number used to connect to the serverInteger numbersNAFrom 1 to 65535
8The Brand
field
11Brand
Enter the value in the fieldSets the name of the brand that is displayed in the third-party clients that support the video transmission via the ONVIF protocolLatin alphabet, Cyrillic, digits and service charactersAxxonSoft 

A line containing a sequence of any characters (letters, digits, and service characters)

129The Model
field
Enter the value in the fieldSets the name of the model that is displayed in the third-party clients that support the video transmission via the ONVIF protocolLatin alphabet, Cyrillic, digits and service charactersPSIMA line containing a sequence of any characters (letters, digits, and service characters)
13DepartmentSelect the value from the listSets the department in which the users are created when they are added via the ONVIF-Server interfaceNames of the Department objects registered in the systemNA

Depends on the number of the departments registered in Axxon PSIM

Out of the group
10The Use Media2 service
checkbox
Set the checkboxEnables the ONVIF 2.X standard instead of ONVIF 1.XBoolean typeSet

Set—the ONVIF 2.X standard is used. The video is transmitted in the H264, H265, MJPEG, or MPEG4 formats

Clear—the ONVIF 1.X standard is used. The video is transmitted in the MPEG, MJPEG, or H264 formats

11The Allow DHCP setting
checkbox
Set the checkboxEnables the DHCP supportBoolean typeClear

SetDHCP is used

ClearDHCP isn't used

12The Discovery mode
checkbox
Set the checkboxEnables the WS-Discovery modeBoolean typeSet

Set—the WS-Discovery mode is enabled

Clear—the WS-Discovery mode is disabled

1314The Use RTSP over HTTP Proxy
checkbox
Set the checkboxRedirects all requests to the RTSP-Server server and ONVIF-Server requests to server on the specified port for the operation behind NATBoolean typeClear

Setthe RTSP-Server server and ONVIF-Server server requests are redirected to the specified port (item 15)

Clearthe RTSP-Server server and ONVIF-Server server requests are transmitted to the port specified in the Connection settings group (see item 5 above)

14The NAT IP
field
Enter the value in the fieldSets the IP address that the ONVIF-server will transmit in responses to clients if clients are behind NATIP addressNADepends on the network settings behind NAT
15The Port
field
Enter the value in the fieldSets the port number for the RTSP-Server server and ONVIF-Server server requests redirection for the operation behind NATInteger numbersNAFrom 1 to 65535
The Authentication group
16NAT IP addressEnter the value in the fieldSets the IP address that the ONVIF Server will use in responses to Clients if the Clients are behind NATIP addressNAThe Department
drop-down list
Select the value from the listSets the department in which the users are created when they are added via the ONVIF-server interfaceNames of the Department objects registered in the systemNA

Depends on the number of the departments registered in Axxon PSIM

Depends on the network settings behind NAT

*Name of the element isn't displayed in the settings panel of the given object.

The Event settings tab

ParameterMethod for setting the parameter valueParameter description RepresentationDefault valueValue range
The ONVIF-server eventgroup*
171The ONVIF-server event
drop-down list
Select the value from the listSets the ONVIF-server event according to the ONVIF specificationList of available eventsNAAccording to the ONVIF specification
182The Computer
drop-down list
Select the value from the list

Sets the Computer object on the basis of which the object is created, that is, the event source in Axxon PSIM

Names of the Computer objects registered in the systemNADepends on the number of the computers in the video surveillance system with distributed architecture
193The Type
drop-down list
Select the value from the listSets the event type, which is the event source in Axxon PSIMNames of the object types registered in the systemNADepends on the number of the created objects in the video surveillance system with distributed architecture
204The Number
drop-down list
Select the value from the listSets the object number, which is the event source in Axxon PSIMSequence of numbersNADepends on the number of the created objects in the video surveillance system with distributed architecture
215

The Name
field

AutomaticallySets the object name, which is the event source in Axxon PSIMNames of the object of the selected type registered in the systemNADepends on the number of the created objects in the video surveillance system with distributed architecture
226The Event
drop-down list
Select the value from the listSets the event name in Axxon PSIMEvent names received from the objects of the selected typeNADepends on the object type
The Transfer parameters group
237The ONVIF-event parameter name
field
AutomaticallySets the ONVIF-event parameter name according to the specificationParameter names of the selected ONVIF-eventNAAccording to the ONVIF specification
248The Event parameter name
field
Enter the value in the fieldSets the event parameter name in Axxon PSIMLatin alphabet, Cyrillic, digits and service charactersNAA line containing a sequence of any characters (letters, digits, and service characters)

*Name of the element isn't displayed in the settings panel of the given object.