The table describes the parameters of the settings corresponding to the elements of the settings panel of the the Telemetry Controller object.
№
| Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | The Identification number* | Automatically | Displays the identification number of the Telemetry Controller object in the video surveillance system with |
distributed architecture |
Digits, letters, periods, hyphen, dash, and underscore | NA | Depends on the number of the Telemetry Controller objects in the video surveillance system with |
distributed architecture | |||
2 | The Name* | Enter the value in the field | Sets the name of the Telemetry Controller object in the video surveillance system with |
distributed architecture | Latin alphabet, Cyrillic |
and service characters | Telemetry Controller |
A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 | |||
3 | The Disable | Set the checkbox | Disables the Telemetry Controller object in the video surveillance system with |
distributed architecture | Boolean type | Clear | Set—the Telemetry Controller object is disabled and isn't used Clear—the Telemetry Controller object is enabled and is used |
4 | The Computer | Select the value from the list | Sets the Computer parent object of the system with |
distributed architecture to which the |
given Telemetry Controller object belongs |
Names of the Computer objects registered in the system | Name of the Computer parent object | Depends on the number of the Computer objects in the video surveillance system with |
distributed architecture | ||||||
The Settings group | ||||||
5 | The Controller type* | Select the value from the list | Sets the data communication protocol with the PTZ device via the serial (COM) port. Data communication protocols are supplied by the PTZ devices manufacturers |
Names of the PTZ devices integrated in the system | Videotec | Corresponds to the list of the PTZ devices integrated in the system | ||||
6 | The Port | Select the value from the list | Sets the number of the computer COM port used to connect the PTZ devices | List of the available COM ports | COM1 | Depends on the number of COM ports on the server or Remote Administrator’s workstation. If you select a non- |
empty value, the local COM port has a higher priority than other devices when processing commands to the PTZ device. Otherwise, the COM port priority is set by default | ||||||
7 | The Rate | Select the value from the list | Sets the data communication rate via the COM port | kB/s | 9600 | From 300 to 256000 |
8 | The Parity | Select the value from the list | Sets the parity check mode for the data transfer via the COM port |
Names of the parity check |
modes | None | Even, Odd, None, Mark, Space | ||||
9 | The DTR | Set the checkbox | Sets the power supply to the PTZ device via the output of the DTR COM port | Boolean type | Set | Set—the power is supplied via the DTR port output Clear—the power isn't supplied via the DTR port output |
10 | The RTS | Set the checkbox | Sets the power supply to the PTZ device via the output of the RTS COM port | Boolean type | Set | Set—the power is supplied via the RTS port output Clear—the power isn't supplied via the RTS port output |
*Name of the element isn't displayed in the settings panel of the given object.