Go to documentation repository
...
The table describes the setting parameters corresponding to the elements of the settings panel of the Program object.
№
| Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | The Identification number* field | Automatically | Displays the identification number of the Program object in the video surveillance system |
Digits, letters, periods, hyphen, dash, and underscore | NA | Depends on the number of the Program objects in the |
video surveillance system with distributed architecture | ||||||
2 | The Name* field | Enter the value in the field | Sets the name of the Program object | Latin alphabet, Cyrillic, digits and service characters | Program | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | The Disable checkbox | Set the checkbox | Disables the Program object | Boolean type | Clear | Set—the Program object is disabled and isn't used Clear—the Program object is enabled and used |
4 | The Time schedule | Select the value from the list | Sets the time period during which the given program operates | Name of the |
time schedule registered in the system | Never | Never—this program isn't executed Always—this program is always executed List of the created time schedules—the program is executed within the time period specified in the time schedule | ||||
The Computers group | ||||||
5 | The Select an element checkbox | Set the checkbox | Sets the computer on which the given program is executed | Boolean type | Clear | Set—the program is executed on the specified computer Clear—the program isn't executed on the specified computer |
6 | The Computer field | Automatically | Sets the computer in the local network | Computer name in the local network | Computer name in the local network | A line containing a sequence of any characters (letters, digits, service characters), case-insensitive. Number of characters—60 |
7 | The Name |
field | Automatically | Sets the name of the computer | Name of the Computer object registered in the system | Name of the Computer object registered in the system | A line containing a sequence of any characters (letters, digits, service characters), case-insensitive. Number of characters—60 | |
Out of the group | ||||||
8 | The Filter field | Enter the value in the field | Sets to pre-filter events processed by the program | Latin alphabet, Cyrillic, digits |
and service characters | NA | A line containing a sequence of any characters (Latin letters, digits, service characters), case-insensitive. Number of characters—unlimited. The filter format is TYPE|ID|EVENT divided by semicolon. For example, the CAM||MD_STOP;CAM||MD_START format filters Alarm and Alarm end events from all Camera objects | ||
9 | The Text editor field | Enter the value in the field | Enters the text of the executed program | Latin alphabet, Cyrillic, digits |
and service characters | NA | A line containing a sequence of any characters (Latin letters, digits, service characters), case-insensitive. Number of characters—unlimited |
* Name of the object element isn't displayed on the settings panel .of this object