Set the Shutdown with administrator passwordcheckbox.
Click the Apply button.
...
Go theUserstab in theSystem settingswindow.
In the object tree, in the lower left part of the window, select the same-name object that corresponds to the account of operator permissions. As a result, theMaintab on the settings panel of the User permissionsrightsobject opens. Image RemovedImage Added
Configure the shutdown ofAxxon PSIM:
Clear the Allow downloading without operator password (the Users tab) and Shutdown with administrator password (theProgramming tab) checkboxes to shut down with operator password only;
Set the Shutdown with administrator password (theProgramming tab) checkbox and clear the Allow downloading without operator password (the Users tab) checkbox to shut down with operator or administrator password;
Clear the Allow re-registration(the Users tab) checkbox. In the latter case, the Runmenu of theMain control paneldoesn't contain the Shut Downoption. This menu item appears only after you enter the administrator password in the password query window. To shut down the system, you must enter the administrator password again. Thus, we recommend additionally using the option of shutting downAxxon PSIMwith the administrator password only.