Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The To configure the neurotracker track counter is configured as follows, do the following:

  1. Go to the settings panel of the Track counter object
  2. settings panel
  3. , which is created on the basis of
  4. the
  5. the Neurotracker object.
    Image Modified
  6. On
  7. Specify the surveillance area on the video image
  8. , specify the surveillance area, within
  9. in which the
  10. track counter will count the
  11. neurocounter counts objects:
    1. Click the Settings button (1). As a result, the Detection settings window
  12. will open
    1. opens.
      Image Modified
    2. Click the Stop video button (1) to capture a frame of the video image.
    3. Click the Area of interest button (2) and

  13. select
    1. specify the area

  14. ,
    1. within which the

  15. track counter will count the
    1. neurotracker counts objects (3).


  16. Image Removed
    1. Info
      titleNote

      To delete the selected area, click the

  17. Image Removed button
    1. Image Added button (4).

    2. Click the OK button (
  18. 4
    1. 5).
  19. If you don't set the Generate event only when the number is changed checkbox (4)
  20. is not set
  21. , then from the Counter period drop-down list (2), select the counter period time unit: seconds, minutes, hours, days. Then in the field (3),
  22. specify
  23. enter the time
  24. in
  25. through which the event containing
  26. the total
  27. the total number of objects recorded for
  28. a
  29. the given time period
  30. will be generated
  31. is generated.
    The allowable range of values for the time units: seconds, minutes, hours—from 1 to 100, days—from 1 to 20.
    Info
    titleNote

    If the entered value exceeds the allowable range, then after you click the Apply button, the maximum value is set automatically.

  32. Set

  33. the 
  34. the Generate event only when the number is changed checkbox (4) if

  35. it is necessary
  36. you want to generate events only when changing the number of recorded objects

  37. changes
  38. .

    Info
    titleNote

    If you set this checkbox

  39. is set
  40. ,

  41. the
  42. the Counter period field becomes inactive, and the specified value of the counter period is ignored.

  43. If objects are lost during the track counter operation, then for more accurate counting, set the Set number of frames for counting checkbox (5)

  44. and
  45. , and in the field (6), enter the number of frames that

  46. will be
  47. are analyzed to calculate the average

  48. objects
  49. object number.

    Info
    titleNote

    This feature works only if

  50. the 
  51. you set the Generate event only when the number is changed checkbox

  52. is set
  53. .

    The value of the number of frames for counting is selected experimentally depending on the neural network used. Recommended values are: 3, 5, 7, 9.

  54. Click the Apply button (7).

The Configuring the neurotracker track counter is configuredcomplete.

Info
titleNote

To display the events that were are generated by the neurotracker the neurotracker track counter in the Event Viewer, it is necessary to event viewer, you must configure a filter for the track counter. For details, see see Configuring event filters for displaying in the Event viewer.