Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Tip

Designation in the table

Description
Functionality
Monitoring

Integration module only allows you to receive events. Control and configuration from Axxon One + ACFA is impossible

Monitoring, control

Integration module allows you to receive events and control objects, for example, from a map: arm/disarm alarm loops, command actuating devices, and so on. Configuration from Axxon One + ACFA is impossible

Monitoring, control, configuration

Integration module allows you to perform any operations (equipment configuration, control, monitoring) using only Axxon One + ACFA

Auto configuration

Integration module allows you to read configuration from equipment and build the corresponding object tree in Axxon One + ACFA

Licensing

ACFAReader

Module type in ACFA Reader price list

ACFASensor

Module type in ACFA Sensor price list

ACFAFence

Module type in ACFA Fence price list

Type of integration

Low-level protocol

System developer has provided events, reactions, commands as a set of bytes for connection to the equipment, so the equipment can be directly connected to Axxon One + ACFA

SDK

Software Development Kit. System developer has provided an SDK, so the equipment can be directly connected to Axxon One + ACFA

Communication server

Driver program. System developer has provided their own driver (a software layer between AxxonSoft software and the equipment in which events, reactions, configuration commands, and status polling are embedded) for connecting the equipment. In order to connect the equipment to Axxon One + ACFA, you must install third-party service software and configure its interaction with Axxon One + ACFA. COM server and OPC server are examples of such programs

API

Application Programming Interface. System developer has provided an API for working with the equipment via the Web-server embedded into the equipment, so the equipment can be directly connected to Axxon One + ACFA

SOFT-SOFT

System developer has provided an API to enable the use of your commands in Axxon One + ACFA and the Axxon One + ACFA commands in your software. In order to connect the equipment to Axxon One + ACFA, you must install the full version of the third-party software and configure its interaction with Axxon One + ACFA. Database synchronization is a variant of SOFT-SOFT type of integration at the level of sharing one database between two software, for example, for access to Event Viewer

Info
titleNote

For SOFT-SOFT type of integration, the equipment connection interface isn't specified, since Axxon One + ACFA isn't connected directly to the equipment, but to third-party software. We recommend you to contact the manufacturer of such software to specify the equipment connection interface.

Generic protocol

Generic protocol integration:

  • OPC and BACnet are industry standards. System developer makes OPC server or BACnet server implementation for their devices and transfers data via OPC or BACnet protocol. Axxon One + ACFA is a client of such servers and receives data (events, reactions, configuration commands, and so on).
  • SNMP is a network protocol, which allows monitoring of some devices.
  • Modbus is a communication protocol, which allows devices to communicate with each other, exchange data and commands. You can use it to monitor and control various devices such as sensors, actuating devices and controllers
Drivers Pack

Integration by one of the above methods via Drivers Pack. When you use this type of integration, you must install Axxon One, ACFA, and Drivers Pack to work with the equipment

List of integrated equipment in ACFA

Name of the integration module

Integrated software, hardware

Functionality

Licensing

Information on manufacturer

Type of integration

Hardware connection interface

ACFA version

ACS integration modules

Hikvision

  • DS‑K1T342MFWX‑E1
  • DS-K1T671TM-3XF

Monitoring, control

Works with the Access Manager integration module

Per:

  • sensor (ACFASensor)
  • reader (ACFAReader)

 

Hikvision USA
18639 Railroad Street, City of Industry, California 91748
Tel: +1-909-895-0400
Toll Free: +1-866-200-6690 (U.S. and Canada only)
Technical Support: tel: 909-612-9039 or email: techsupport.usa@hikvision.com
Sales: sales.usa@hikvision.com
http://www.hikvision.com/us/

SDK+API

Ethernet

15.0

FSA integration modules

CORTEX: WinSC

CORTEX Security Commander for Windows v5.xx to monitor fire and security alarm system in Windows OS

Monitoring, controlPer zone (ACFASensor)

KORTEKS, SIA

Address: Liksnas street 7, Riga, LV-1003, Latvia
Phone: +371 67 505 603
Fax: +371 67 505 604
Website: cortex.eu
Email: sales@cortex.lv
Support: support@cortex.lv

SOFT-SOFTNA4.0
Hikvision: IP Receiver Pro
  • Hik IP Receiver Pro software version 2.2.1.3, build 20241029
  • Hikvision DS-PHA48-EP control panel

Monitoring, control


Per zone (ACFASensor)

HANGZHOU HIKVISION DIGITAL TECHNOLOGY CO. LTD

Address: No.555 Qianmo Road, Binjiang District, Hangzhou 310051, China

Phone: +86-571-8807-5998

Website: www.hikvision.com

Support email: support@hikvision.com

SOFT-SOFTEthernet4.0
Mavili

Sprvsr+ Web Plug-in Web software

Hardware:

  • ML-1110.SCI analog fire detector
  • ML-1362.SCI and ML-1372.SCI monitoring and control modules
Monitoring, controlPer device (ACFASensor)

Mavili Elektronik A.Ş
Address: Şerifali Mahallesi Kutup Sokak No:27/1-2-4 Ümraniye TR-34775 İSTANBUL
Tel: +90 216 466 45 05 (pbx)
Fax: +90 216 466 45 10
Website: www.mavili.com.tr

Email: mavali@mavali.com.tr

SOFT-SOFTEthernet5.0
Protege

Protege GX version 4.3.352.7

Monitoring, control

Per:

  • input (ACFASensor)
  • sensor (ACFASensor)

Integrated Control Technology (ICT) Ltd

Address: 4 John Glenn Avenue, Rosedale, Auckland 0632, New Zealand

Website: ict.co

Email: support@ict.co

SOFT-SOFTNA6.0
RISCO: LightSys

All models of the ProSYS™ Plus Main Board series, as well as LightSys Plus and LightSys 2 boards.

Сharacteristic:

  • Class 3 or 2, optional
  • Number of zones: 8–512
  • Number of partitions: 32
  • Groups per partition: 4 
  • Number of outputs: 6–262
  • Number of user codes: 500 
  • Number of events in the log: 2000
  • Selected zone resistance
Monitoring, controlPer zone (ACFASensor)

RISCO LTD

Address: Israel, 75655 Rishon LeZion, 14 Hachoma Street

Phone: +972-3-9637777

Fax: +972-3-9616584

Website: www.riscogroup.com

Email: info@riscogroup.com

Sales department: sales@riscogroup.com

Low-level protocolEthernet1.0
Rozetatech: ObeliskRozetatech OBELISK-1.0 GatewayMonitoring, controlPer device (ACFASensor)

Rozetatech Co Ltd

Address: B-1710, 2nd Woollim Lions Valley.14, Sagimakgol-ro 45beon-gil, Jungwon-gu, Seongnam-si, Gyeonggi-do

Phone: +82-31-736-5308 

Website: www.rozetatech.co.kr

Email: contactus@rozetatech.co.kr

SOFT-SOFTNA1.0
Satel2 ETHM-ASatel2 ETHM-AMonitoring, control

Per:

  • zone (ACFASensor)
  • relay (ACFASensor)

SATEL sp. z o.o.

Address: Budowlanych 66, 80-298 Gdansk, Poland

Phone: +48 58 320 94 00

Fax: +48 58 320 94 01

Website: www.satel.pl

Email: satel@satel.pl

Low-level protocolEthernet1.0
Satel2: Panel
  • Integra 32
  • Integra 64
  • Integra 64 Plus
  • Integra 128 Plus
  • Integra 128-WRL
  • Integra 256 Plus
Monitoring, control, configuration

Per:

  • zone (ACFASensor)
  • output (ACFASensor)

SATEL sp. z o.o.

Address: Budowlanych 66, 80-298 Gdansk, Poland

Phone: +48 58 320-94-00 

Fax: +48 58 320-94-01

Website: www.satel.pl

Email: satel@satel.pl

Low-level protocolEthernet1.0
UniPOS: 7000All interactive fire control panels of the 7000 series are integratedMonitoring, control, configuration

Per:

  • zone (ACFASensor)
  • UNIPOS7000 CAN (ACFASensor)
  • UNIPOS7000 MODULE (ACFASensor)
  • UNIPOS7000 BIO DEVICE (ACFASensor)
  • UNIPOS7000 LOOP (ACFASensor)
  • UNIPOS7000 LOOP DEVICE (ACFASensor)
  • UNIPOS7000 BUI MODULES (ACFASensor)

Unipos

Address: Sofia, Bulgaria, Mladost 1, 1 Efr. Nikola Paskalev Str., next to block 56

Phone: + 359 2 97 444 69

Website: www.unipos-bg.com

Email: office_sofia@unipos-bg.net

Low-level protocolRS-2321.0

PID integration modules

DEA: FUSION P2PBR-FSP2PLT-CTRLMonitoring, control

Per:

  • Line object (ACFAFence)
  • Input object (ACFASensor)

DEA Security

Phone: +39 0187 699233

Fax: +39 0187 697615

‍Website: https://www.deasecurity.com/en/

Email: dea@deasecurity.com
deasecurity.srl@pec.deasecurity.com

Low-level protocolEthernet2.0
Vanderbilt: SPC panel
  • SPC4320x
  • SPC6330
Monitoring, controlPer zone (ACFASensor)

ACRE Security

Website: acresecurity.com

Low-level protocolEthernet1.0
Peridect+
  • PERIDECT-CUP+
  • PERIDECT-LCP+

  • PERIDECT-DSP+
  • PERIDECT-LIP+
Monitoring, controlPer detector (ACFAFence)

SIEZA

Address: Buštěhradská 109, Dubí, 272 03 Kladno, Czech Republic

Website: https://www.sieza.com/en/company/

Email: sieza@sieza.com 

SOFT-SOFTEthernet3.0

...