titleNote

For example, an operator can exit alarm mode to view the video archive related to the alarm

To configure alarm handling in the system, you must perform the following steps:

  1. Go to Settings Þ Options Þ Options  Alarm Management(1-2). 
  2. In the Alarm pending time group, enter the time in seconds during which it is necessary to accept the alarm for processing before it is assigned the Unclassified status (3).
  3. In the Operator's idle time field, enter the time in seconds during which an operator who accepted an alarm for processing and exited alarm mode without evaluating it must return to alarm mode (4).
  4. Click the Apply button.

...