To install ATM-Intellect in the ATM-Intellect Workstation configuration, do the following:

  1. Start the file setupATMIntellARMsetup.exe from the installation kit. The installation wizard informs that the installation process has begun.
    Image Modified
  2. You are prompted to start installation. Click the Next button.
    Image Modified
  3. In the License agreement window read the terms of the End-User License Agreement . Set the switch into the I accept the terms in the license agreement position and press Next.
    Image Modified
  4. You will see the MonitorSSTV database installation page. In the Name field specify the name of the database under which it will be registered.
    Image Removed

    Info
    titleNote.
    The default name of the database is MonitorSSTV and its files are located in the SQL Server folder.
  5. Click the Install button.
  6. Set the ATM-Intellect Workstation installation type. Click Next.
    Image Added

  7. A dialog box to for choosing installation type will be displayed. If Intellect software is installed as a service and ATM-Intellect Workstation is to be installed as a service as well, set the Install ATM Intellect as a service checkbox. Click Next.
    Image Added
  8. A dialog box to configure database connection will be displayed. Select the database server name and set up the connection parameters. 

    Select the name of the database server and connection settings in the opened pane Data Link Properties. The MS SQL Server 2008 name of the database server consists of two parts – the name of the PC and the name of the server instance, e.g. SHOWROOM5\SQLEXPRESS or (local)\SQLEXPRESS. If a password is used, make sure to check the box Allow saving password.
    Image Removed

    Info
    titleNote.
     In

    In the

    1. Select or enter a server name field  specify

    Select database Server from the drop-down list field specify the "127.0.0.1" value instead of computer name or "(local)" value, e.g. "127.0.0.1\SQLEXPRESS". Otherwise ATM-Intellect Workstation will lose connection with its local database when the network cable is disconnected.


    Image Added

  9. In the Database field specify the name of the database or select it in the list of databases, which are created in the server, and click <<. 

    If the settings are correct and the database server runs successfully, you will see the message Test connection succeeded on clicking the Test connection button. Otherwise, you will see an error message.
    Image Removed

    Info
    titleNote.
     if not-English version of MDAC components is installed on the PC, the dialog boxes Data Link Properties and Microsoft Data Link will not be in English.
    Click OK in Data Link Properties
    The default name of the database is MonitorSSTV and its files are located in the SQL Server folder.


    Image Added

    Click Next.
  10. Click Install on in the next panedialog box.
    Image RemovedImage Added
  11. Installation begins.
    Image RemovedImage Added
  12. After the final installation tasks are completed, the wizard informs that the software has been successfully installed. Click Finish.
    Image RemovedImage Added

ATM-Intellect Workstation installation is completed.