Unable to render embedded object: File (books.jpg) not found.
Go to documentation repository
Page History
Data monitoring is set up as follows:
- Go to the ATM-Intellect Workstation setting panel.
- Click the Monitoring… button. The dialog box to set up monitoring appears.
- Go to the Retranslation tab (1).
If Central Security Console (CSC) is installed on CCRVS, enable the
forwardingForwarding alarm messages option and specify the corresponding IP address and TCP port (
1).2).
Info title Note. This setting is for compatibility with old versions of ATM-Intellect. It is not used in current versions.
- If system health information of the local video surveillance systems must be transmitted to ATM-Intellect Workstation TC, enable the forwarding Forwarding status info option in the opened pane panel (23). Specify the IP address and the TCP port of the PC on which ATM-Intellect Workstation TC is installed.
- To control the normal operation of the Data loader for Monitoring of ATM-Intellect Workstation, the following configurable parameters are used:
- ID is the unique ID number of ATM-Intellect Workstation (similar to ID in the ATM-Intellect Pro settings) – (3)4).
- Threshold (files) is the number of files in the exchange folder of the Data loader, on exceeding which the message Software error (Data loader) is sent to ATM-Intellect Workstation TC (45).
- Press OK (56).
Configuring data monitoring is completed.
Overview
Content Tools