Let us consider the following situation: electrical power supply has switched off and the UPS has switched to battery mode (ID Code = 2000), and

...

electrical power supply has been restored a while later (ID Code = 1003).

In this case to configure events notifying do the following:

  1. In the list of events, select the UPS On Battery event and, for this event, enable the option Run Command File.
  2. To the right of the Run Command File line, click the Options... button. In the dialog box that appears, indicate the full path to the StateUPS utility, which is what we want has to start whenever this event occurs. Enclose the path in double quotes. Type a space and then indicate the ID code for the UPS On Battery event (which is equal to 2000 ) (see Configuring PowerChute plus utility).
  3. The equivalent actions for the Utility Power Restored event are shown in figures below.

...

Every time the StateUPS utility is launched, a log file is created in the system folder of the operating system (System32)<Intellect installation>\Vhost\UPS folder, with a name resembling:

...