  1. Select the entry to which the access sensor is connected (Fig. 3.34, 1). If the access sensor is not connected, then set the None value. In this case, skip the following steps.

...

  1. Image Added
  2. In the Active state list select the level of signal at discrete input at which the sensor triggering is detected (Fig. 3.34, 2).
  3. In the corresponding list select the relay locking mode when the access sensor is triggered (Fig. 3.34, 3). By door opening – relay is disabled at rising edge of access sensor triggering. By door closing - relay is disabled at falling edge of access sensor triggering.
  4. If the access event is to be taken into consideration, then select the Yes value in the corresponding list (Fig. 3.34, 4).
  5. If the door hack is to be taken into consideration, then select the Yes value in the corresponding list (Fig. 3.34, 5).
  6. Click the Apply button to save all changes.

...