Castle ACS Access point is configured on the settings panel of the Castle Access point object. This object is created on the base of the Castle server object in the Hardware tab of the System settings dialog box (Fig. 3.4 1).

Image Added

The Anchor_Ref402957381_Ref402957381Fig. 3.4 1 The Castle access point object
The Access point object is registered automatically when reading Castle ACS configuration.

The following parameters are automatically specified when reading Castle ACS configuration:

  1. Access point ID in the Castle ACS database (Fig. 3.4 2, 1);.

...

  1. Image Added
  2. Access

...

  1. access

    point configuration (

    Fig. 3.4 2,

    2)

    ;

    .

    Info
    titleNote

...

  1. Access point configuration is set using the switch on the card of corresponding Castle ACS controller (see reference documentation about Castle ACS).


  2. access Access control mode (Fig. 3.42, 3).

Castle ACS access points are configured as follows:

  1. In the Entry dropdown drop-down list, select the Region object corresponding to the area on the side of entrance to exit from the access point (Fig. 3.4 2, 4).
  2. In the Exit dropdown drop-down list, select the Region object corresponding to the area on the side of exit from entrance to the access point (Fig. 3.4 2, 5).
  3. Set parameters of access control at entrance (Fig. 3.4 2, 6):
    1. In the Entry

    dropdown
    1. drop-down list, select the one that will decide whether to give access or not and whether to register it or not

    1. Intellect Server or operator;

      Info
      titleNote

...

    1. To process the request operator is to create a

...

    1. Event Manager interface object and configure it for the Operator's query (Access granted) event. For more information about this object and its functions, please refer to

...

    1. Event Manager Module Settings and Operation Guide.


    2. If it is considered that passing is performed just after placing the access card to the reader, then
    check
    1. set the Don't wait access cycle for exit checkbox. If the passing is considered to be performed only after passing the access point (i.e. door sensor is triggered), uncheck this checkbox.
  1. Set parameters of access control at exit (Fig. 3.4 2, 7). The parameters are the same as those of access control at entrance (see the previous item).
  2. Click the Apply button to save all changes (Fig. 3.4 2, 8).
  3. Repeat steps 1-9 for all required Castle ACS access points.

...