The controller The ZK C3-100 is , ZK C3-200, ZK C3-400 controllers are configured on the settings panel of the corresponding objects AC ZK Controller C3-100 object which is , AC ZK Controller C3-200 and AC ZK Controller C3-400 which are created on the basis of the AC ZK Teco object on the Hardware tab of the System settings dialog window.
To configure the C3-100 controller
Info | ||
---|---|---|
| ||
The ZK Teco controller will be configured using the ZK C3-100 as an example. Other controllers are configured in the same way. |
To configure the ZK Teco controllers, do the following:
- Go to the settings panel of the AC ZK Controller C3-100 objectcorresponding ZK Teco controller.
- From the Gate: drop drop-down list (1), select the type of controller connection (see Configuring the connection : via Ethernet or standard or Configuring the connection via RS-485 standard (1).
- In the Password: field field (2), enter the password for controller connection (2).
- In the IP: field If the Ethernet connection type was selected, then enter the IP - address of the controller in the IP field (3).
- If the the RS-485 standard connection type was selected, then select the connection COM port number from the Address drop-down list (3).
From the Anti-passback
: dropdrop-down list (4), select the
rulemode of anti-passback operation:
Mode
...
Description
Controller
Disable
The anti-passback function is disabled All controllers Readers of Door 1 The anti-passback function is enabled between the readers of Door 1 ZK C3-100, ZK C3-200 Readers of Door 2 The anti-passback function is
...
enabled between the readers of Door 2 ZK C3-200 Readers of door 1, readers of door 2 The anti-passback function is enabled between the readers of Door 1 and Door 2 respectively ZK C3-200 Door 1 and 2 The anti-passback function is enabled between the readers of Door 1 and Door 2 ZK C3-200, ZK C3-400 Doors 3 and 4 The anti-passback function is enabled between the readers of Door 3 and Door 4 ZK C3-400 Doors 1 and 2, doors 3 and 4 The anti-passback function is enabled between the readers of
...
Door 1, Door 2, Door 3 and Door 4 ZK C3-400 Doors 1, 2 and doors 3, 4
The anti-passback is enabled between Door 1, 2 and Door 3, 4 ZK C3-400 Door 1 and doors 2, 3 The anti-passback is enabled between Door 1 and Door 2, 3 ZK C3-400 Door 1 and doors 2, 3, 4 The anti-passback is enabled between Door 1 and Door 2, 3, 4 ZK C3-400 From the Interlock drop-down list (5), select the mode of doors interlocking:
Mode
Description
Controller
Disable
The interlock function is disabled All controllers Door 1 and 2 Doors 1 and 2 are interlocked mutually ZK C3-200, ZK C3-400 Door 3 and 4 Door 3 and door 4 are interlocked mutually ZK C3-400 Doors 1, 2 and 4 Door 1, door 2 and door 4 are interlocked mutually ZK C3-400 Doors 1 and 2, doors 3 and 4
Door 1 and door 2 are interlocked mutually, door 3 and door 4 are interlocked mutually ZK C3-400 Doors 1, 2, 3 and 4 Door 1, door 2, door 3 and door 4 are interlocked mutually ZK C3-400
The Interlock function is always disabled for the single-door controller (4)Info title Note To open one of the interconnected doors, the other interconnected doors in the group must remain closed. This means that in a group of interconnected doors, only one door can be opened at a time
.
- From the Backup period: drop drop-down list (6), select the time interval in minutes for ??? (5).the automatic backup of data of the specified type (see Managing the configuration of a ZK controller).
Set the Watch dog checkbox
??? (6).
Note. The version of firmware and serial number of controller will automatically displayed in the corresponding fields while connecting the controller.
- Click the Apply button (7).
(7) to enable the automatic data backup.
Click the Apply button (9).
Info title Note. After a successful connection with the controller is established, the firmware version and the controller serial number will automatically be displayed in area (8).
Configuring the ZK C3-100, ZK C3-200, ZK C3-400 controllers is now Configuring of the C3-100 controller is completed.