The Control panel object is designed used to register and configure a specialized control panel used for to manage the PTZ control devices in the Intellect™ system Intellect.
The settings panel of the Control panel object is shown in the figure.
Table describes the parameters of the settings corresponding to the elements of the settings panel of the Control panel object.
№
| Parameter | Method for setting the parameter value | Parameter description |
Representation | Default value | Value range | |
1 | Identification number* | Automatically | Displays the identification number of the Control panel object in the |
digital video surveillance system |
with the distributed architecture | Numbers, letters, periods, hyphen, dash and underscore | - | Depends on the number of the Control panel objects in the digital |
video surveillance system with the distributed architecture | ||
2 | Name* | Enter the value |
into the |
field |
Sets the name of the Control panel object in the digital |
video surveillance system |
with the distributed architecture | Latin, Cyrillic characters and service characters | Control panel | A line containing a sequence of any |
characters (letters, digits, service characters |
except > and < |
characters), |
case- |
insensitive. Number of |
characters — from 1 to 60 |
3 | Disable |
Is identified by the check mark
Set the checkbox | Sets the state |
of the Control panel object (enabled or disabled) in the digital |
video surveillance system |
with the distributed architecture | Boolean type |
Not available
Clear | Set— |
the Control panel object |
is disabled and isn't used Clear— |
the Control panel object is enabled and is |
used | |
4 | Telemetry |
Controller | Select the value |
from the list |
Sets the Telemetry Controller parent |
object of the digital |
system with the distributed architecture, to which the given Control panel object |
belongs | Name of the Telemetry |
Controller objects registered in the system | Name of the Telemetry Controller parent |
object |
Depends on the number of |
telemetry controllers in the digital |
video surveillance system with the distributed architecture | ||||||
The Settings |
group | ||||||
5 | Port |
Select the value from the list |
Sets the number of the computer serial (COM) port |
used to connect the Control panel |
List of available COM |
ports | COM1 | Depends on the number of COM ports |
on the |
Server or Remote Administrator |
's workstation | |
6 | Speed |
Select the value from the list |
Sets the data communication |
speed of the serial (COM) port |
Kb/ |
s | 9600 | From 300 to 256000 |
7 | Parity |
Select the value from the list |
Sets the parity check mode for the data transmission over the serial (COM) port |
List of the parity check modes |
None | Even, Odd, None, Mark, Space |
8 | DTR |
Is identified by the check mark.
Set the checkbox | Sets |
whether or not the power should be supplied to the |
Control panel via |
the output of the DTR serial (COM) port | Boolean type |
Set |
Set—the power will be supplied via the DTR port |
output |
Clear—the power will not be supplied via the DTR port |
output | |
9 | RTS |
Is identified by the check mark.
Set the checkbox | Sets |
whether or not power should be supplied to the |
Control panel via the output of the RTS serial (COM) port |
Boolean type |
Set |
Set—the power will be supplied via the RTS port |
output |
Clear—the power will not be supplied via RTS port |
output | |
10 | Priority |
Select the value from the list |
Sets the priority of the PTZ |
devices control using the Control panel |
Names of priorities used to control the PTZ |
devices | Low | Control prohibited |
—the PTZ |
device cannot be controlled using the Control panel |
Low |
—the |
PTZ device can be |
controlled after it is controlled by the devices with the standard or high |
priority Standard |
—the |
PTZ device can be |
High – the PTZ with the given priority will be controlled first.
controlled after it is controlled by the device with the high priority High—the PTZ device is controlled first |
*Name *The name of the element is not displayed in the settings panel of the given object.