The Macro object is designed used to support the automatic execution of a pre-defined sequence of commands upon occurrence of certain events, registered by the Intellect™ system Intellect.

The settings panel of the Macro object is shown in the figure.

Image Modified

The table Table describes the setting parameters of the settings corresponding to the elements of the settings panel of the Macro object.

Parameter

Method for

entering

setting the parameter value

Parameter description

Symbols used

Representation

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Macro

command

object in the digital video surveillance system

.

Numbers, letters, periods, hyphen, dash and underscore

Sequence of numbers

-

Depends on the number of the Macro

command

objects in the digital

distributed

video surveillance system

.

with distributed architecture

2

Name*

Enter the value

in

into the field

Defines

Sets the Macro

command object

 object name.

Latin, Cyrillic and service characters

Macro

A line containing a sequence of any

symbols

characters (letters, digits, service characters

apart from

except > and <

symbols

characters), case-insensitive.

Number of

symbols – from

characters—from 1 to 60

.

3

Disable

Is identified by the check mark

Defines the Macro command object status

Set the checkbox

Sets the state (enabled or disabled)

.

of the Macro object 

Boolean type

Not available

Yes

Clear

Setthe Macro

command

object is disabled and

is not in use

isn't used

Clearthe Macro

No – the macro command

object is enabled and

is in use.

used

The Settings

Group

group

4

State

Enter the value

in

into the field

Defines

Sets the message displayed in the information board of the main menu of

the

Intellect

system

, when the given macro

command

is running

.

Latin, Cyrillic and service characters

Not defined

1.

Standard

no message will be displayed in the information board of the main menu of

the

Intellect

system

.

2.

A line containing a sequence of any

symbols

characters (letters, digits, service characters), case-insensitive.

Number of

symbols –

charactersfrom 1 to 60

.

5

Local

Is identified by the check mark

Defines

Set the checkbox

Sets the computers, which will execute the given macro

command

(all computers of the digital

distributed

video surveillance system with distributed architecture or only the given computer).

Boolean type

Not available

Note. This checkbox does not apply to hide and show reactions of any Display. Regardless of the checkbox, when called from the Server/RAW, the reactions are executed on the Server/RAW and all connected Clients; when called on the Client, the reactions are executed only on the Client

Boolean type

Clear

Set—the macro will be executed only on the given computer

Clear—the given macro will be executed on

Yes – the given macro command will be executed by

all computers of the digital

distributed

video surveillance system

.No – the macro command will be executed only by the given computer.

with distributed architecture

6

Hidden

Is identified by the check mark

Defines

Set the checkbox

Determines, whether or not the name of this macro

command

will be displayed in the main control panel of

the

Intellect

system

to be

launched

started manually

.

Boolean type

Not available

Clear

Set— the name of the macro will not

Yes – no macro command will

be displayed in the main control panel of

the

Intellect

system.

Clearthe name of

No

the macro

command

will be displayed in the main control panel of

the

Intellect

system.

The Events

Subgroup

subgroup

7

Type

Is selected

Select the value from the list

Defines

Sets the type of objects in the digital

distributed

video surveillance system with distributed architecture, in which

registration of events initiates macro command execution.

the event registration triggers a macro

Types of objects registered in the system

.

Empty field

-

Depends on the total number of the types of objects created in the digital

distributed

video surveillance system

.

with distributed architecture

8

Number

Is selected

Select the value from the list

Defines

Sets the identification number of the object in the digital

distributed

video surveillance system with distributed architecture, in which

registration of events initiates macro command execution.

the event registration triggers a macro

Sequence of numbers

Empty field

-

Depends on the total number of the

given types of objects

objects of the specified type created in the digital

distributed

video surveillance system

.

with distributed architecture

9

Name

Automatically

Displays the name of the selected object in the digital

distributed

video surveillance system

.

with distributed architecture

Name

Names of

the 

the objects of the

same

specified type registered in the system

Empty field

-

A line containing a sequence of any

symbols

characters (letters, digits, service characters), case-insensitive.

Number of

symbols –

charactersfrom 1 to 60

.

10

Event

Is selected

Select the value from the list

Defines

Sets the event

, which, when registered

that triggers a macro for the

pre-defined object, initiated macro command execution.

specified object

Names of the events available

Events registered

for the given type of objects

.

Empty field

-

List of events is created

separately

individually for each type of object

.

The Parameters

Subgroup

subgroup

NOTE

Note. The given subgroup is not active for

some

all types of objects

.

11

Name

Automatically

Defines an additional

Sets the name of the additional parameter for the selected type of object in the Events subgroup

.

Latin

,

and service characters

and

, digits

.

Not defined

A line containing a sequence of any

symbols

characters (letters, digits, service characters), case-insensitive.

Number of

symbols – from

characters—from 1 to 60

.

12

Value

Enter the value

in

into the field

Defines

Sets the value for the parameter

of

in the Name column

.

Latin

,

and service characters

and

, digits

.

Empty field

A line containing a sequence of any

symbols

characters (letters, digits, service characters), case-insensitive.

Number of

symbols –

charactersfrom 1 to 250

.

The Action

Subgroup

subgroup

13

Type

Is selected

Select the value from the list

Defines

Sets the type of objects in the digital

distributed

video surveillance system with distributed architecture, to which the command is forwarded, when the conditions

defined

set in the Events subgroup

for

to trigger a macro

command initiation

are met

.

Types

Names of the types of objects registered in the system

.

Empty field

-

Depends on the total number of the types of objects created in the digital

distributed

video surveillance system

.

with distributed architecture

14

Number

Is selected

Select the value from the list

Defines

Sets the identification number of the object in the digital

distributed

video surveillance system with distributed architecture, to which the command is forwarded, when the conditions

defined

set in the Events subgroup

for

to trigger a macro

command initiation

are met

.

Sequence of numbers

Empty field

-

Depends on the total number of the

given types of objects created

objects of the specified type in the digital

distributed

video surveillance system with distributed architecture.

If the field is left blank, the reaction will be performed for all objects of the selected type.

If you enter the # symbol in the field, the identifier of the object from which the event was received will be substituted into the reaction. The object types in the Events and Actions tables may differ. When the macro is run manually from the main control panel, the # symbol is treated as if the field was blank, i.e. the macro is executed for all objects of the selected type.
Example of using the # symbol: disarm the camera if the “Detach” event was received from it

15

Name

Automatically

Displays the name of the selected object in the digital

distributed

video surveillance system

.

with distributed architecture

Name

Names of

the 

the objects of the

same

selected type registered in the system

Empty field

-

A line containing a sequence of any

symbols

characters (letters, digits, service characters), case-insensitive.

Number of

symbols –

charactersfrom 1 to 60

.

16

Action

Is selected

Select the value from the list

Defines

Sets the action, which the given device performs, when the conditions

for

to trigger the given macro

command initiation

are met

.

Actions, registered by

Names of the actions, available in the system for the objects of the

given

specified type

of objects.

Empty field

-

List of events is created

separately

individually for each type of object

.

The Parameters

Subgroup

subgroup

NOTE

Note. The given subgroup is not active for all types of objects

.

17

Name

Automatically

Defines an

Sets the name of the additional parameter for the selected type of object in the Actions subgroup

.

Latin

,

and service characters

and

, digits

.

Not defined

A line containing a sequence of any

symbols

characters (letters, digits, service characters), case-insensitive.

Number of

symbols – from

characters—from 1 to 60

.

18

Value

Enter the value

in

into the field

Defines

Sets the value for the parameter

of

in the Name column

.

Latin

,

and service characters

and

, digits

.

Empty field

-

A line containing a sequence of any

symbols

characters (letters, digits, service characters), case-insensitive.

Number of

symbols –

charactersfrom 1 to 250

.

Outside the groups

19

Response sending delay (sec

.

)

Enter the value

in

into the field

Sets the time period (in seconds) that must pass after the events specified in the Events column occur and before executing the reactions specified in the Actions column.


Note.Iftheeventsreoccurbeforethespecifiedtimeperiodexpires, thereactionexecutionwaitperiod

is

will be prolonged, i.e. reactions will be executed only once when events do not reoccur over the specified period

Sequence of numbers

-

>0

20Fast call

Left-click in the field and press the required key combination

Sets a keyboard shortcut for a macro.

Note.

Integer number

-

>0

 If the same combination of keys is set for several macros, when pressing a key combination, all of these macros will run

Key combinations-Individual keys of the main or numeric keyboard, as well as these keys in combination with Shift, Ctrl and Alt
21Icon typeSelect the value from the list

Sets a set of icons for displaying a macro on the map. By default, an empty value is set for all macros which corresponds to the "Macro 1" icon.

Note. Changing the icon type will take effect after restarting the map interface. To restart the interface, restart Intellect or log in once again under the corresponding Operator account

Available icon types on the map

-Macro 1Macro 7, empty value