Connect(BSTR ip, BSTR login, BSTR password, BSTR arch_password, long param, long port) set up a connection to the Server/Video Gate/Backup Archive.

  • BSTR ip – IP address of the Video server;
  • BSTR login – login to connect to the Server (can be blank);
  • BSTR password – password to set up a connection to the Video server (can be blank);
  • BSTR arch_password – password to access the archive (i.e. admin password,  can be blank);

  • long param – Server role:. The parameter is mandatory.
    • 0 – video server;
    • 1 – backup archive;
    • 2 – videogate;

  • long port – port to connect Video server. 
    • if 0, 1 or 2 are passed, the connection is established with port 900, 901 or 902 correspondingly;

    • if 100 is passed, the connection is with port 10504;

    • if any onter value passed, the connection is with port number "port + 20000". For example, if port=900, the connection is established with server port 20900.

The connection to Server is set up asynchronously.

Note
titleImportant!

If login and password are not specified at Connect() method call, all cameras are viewable in the control. It is to be considered when developing third-party application if access privileges are relevant.

ShowCam

ShowCam(long cam_id, long compress, long show) shows/hides camera on the monitor.

...

Info
titleNote:

 Positioning accuracy can be specified in milliseconds, for instance:

DoReactMonitor(“MONITOR||ARCH_FRAME_TIME|cam<3>,date<02-10 05>,time<12:12:22.345>


Example. Show 2nd stream from camera 14 on Monitor 1:

"MONITOR|1|ADD_CAM|cam<14>,cam_id<14>,compress<1>,stream_id<14.2>"

Exapmle. Set fps = 1 when viewing archive from Camera 11

"MONITOR||CAM_PARAMS|cam<11>;arch_fps<1>"

RemoveAllCams

RemoveAllCams() : long – remove all cameras from the monitor

...

  • WithoutDecode = 0x10 – disable video decoding on the server.
  • WithoutSubtitles=0x20 – disable subtitles.
Info
titleNote

...

The options parameter is created the same as parameters of the CamMonitor.ocx component –

...

see CamMonitor.ocx parameters.

SetParam

SetParam(BSTR param_name, BSTR param_value) - sets the number of camera windows in CamMonitor.

  • BSTR param_name - a string representation of the length or width.
  • BSTR param_value - the number of camera windows.

How to call a function:

Code Block
languagecpp
m_cam.SetParam("monitor_ch", m_NH);