Configure the Suprema BioMini control reader in the Intellect software as follows:
Connect the reader to a Server, download and install driver from the manufacturer's official web site.
Info title Note. Registration on this site is required for download. - Run the Intellect software.
- Create the Suprema BioMini object based on the Computer object on the Hardware tab of the System Settings dialog box.
In the Security Level drop-down list (1) select the fingerprint verification quality level:
Lowest (1/1000) — the lowest level.
Low (1/10 000) — low level.
Normal (1/100 000) — average level.
High - (1/1 000 000) — high level.
Highest (1/10 000 000) — the highest level.
- Click Apply (2) to save the settings.
Info | ||
---|---|---|
| ||
Info | ||
| ||
title | Important!To use the connected Suprema BioMini control reader for enrolling fingerprints in Access Manager, select this reader while configuring the Access Manager – see the Configuring a control readers in the Access Manager section of the Access Manager Module Settings and Operation Guide.
| |
Note | ||
|
Note | ||
---|---|---|
| ||
The module requires the 32-bit version of the Microsoft Visual C++ 2008 redistributable package to be installed. If this component is not installed in your system, use the redist/en/x86/vc90redist.exe installer provided in the ACFA Intellect installation package. |
Configuring Suprema BioMini control reader connection in the Intellect software is reader is completed.