To set up the Vehicle
...
Tracer interface window, do the following:
- Go to the Vehicle tracerTracer settings panel.
- Click the Settings... button button. The Settings dialog window will open in result.
In the Number of events in protocol field (1) field enter the maximum number of events that may be displayed in every protocol of the Active monitor component. Updating the protocol, containing the The update of the protocol which contains the maximum number of events, is performed in a loop: while adding a new event the earlier when the maximum number of events is exceeded, the last event in the queue is deleted.
Info title Note. That entails The question is about two protocols (see the document The Auto-Intellect Software Package: . Operator's Guide):
- The protocol of identified vehicles, containing data about the identified vehicles;
- The alarms protocol, containing data about the vehicles, for which alarms have been registered. The number of alarms is calculated as follows: "Number of events in protocol" minus 2. For example, if 100 is specified as a value of the Number of events in protocol field, then 98 alarms will be displayed in the alarm protocol.
Set the Delete alarms together with the LP (2) check box if it is necessary to delete all the events connected to the last number in the queue when exceeding the specified number of events in the protocol.
- Set the Speed (3) switch the Speed switch (2) to the position, corresponding to the Vehicle's speed unit of measurement. That is to be displayed in the Vehicle tracerTracer window (km/h or mmiles/h).
- On By default, in the Active monitor events events protocol there are displayed the following data for every vehicle is displayed:
- Video frame;
- Identified plateLP number;
- Speed;Plate's recognized
- Name of LP recognizer;
- Date and time of receiving the data;
- Alarm's reason Reason of alarm (only for alarms).
In case if in the Active monitor events protocol there should be displayed only identified number, name of plate's case only the identified LP number, name of LP recognizer, and data date and time of receiving the data for every event, set the data should be displayed for each event in the Active monitor events protocol, check the Reduced view of protocol checkbox (3).protocols (4) checkbox.
- You can There is possibility to create additional Active monitor components (see the document see The Auto-Intellect Software Package: Operator's Guide»). In case if If the alarms protocol is displayed should be displayed only in the main interface component of Active monitor, and not in the additional ones, set check the Protocol of alarms only in main Active Monitor window checkbox window (45) checkbox.
- On default By default, the number of active monitor additional displayed components is of additional Active monitor components to be displayed is not restricted. In case if only one, last created active monitor component is required to If only the most recent additional Active monitor component should be displayed, set the check the Only one additional window active monitor checkbox (5Active Monitor window (6) checkbox.
- Set the Do not display regional code (7) check box if it is necessary to hide the Regional code field from the Active Monitor component.
Set the Display the fields of an external DB (8) check box if it is necessary to display the fields of an external DB in the Active Monitor component when the license plate is found in the external license plate database (see Assigning names to table's columns containing vehicle plates).
Click OK (9) to save the changes and close the Settings dialog window (6).
Info title Note. Click Cancel (10) to close the Settings dialog window without saving the changes (7)the changes.
- Click Apply to save the changes on the Vehicle Tracer settings panel.
The interface settings of the Vehicle Tracer window
...
are completed.