Go to documentation repository
Page History
The IntLab
...
Module object settings panel contains the following interface elements:
The following table describes the elements of the IntLab-Carriages Module Module object settings panel.
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
---|---|---|---|---|---|---|
1 |
Recognition start event drop-down list | Selecting the value in the list | Selecting |
the macro, on which the LP recognition will be started | List of |
accessible Macro objects |
<none> | Depending on number of |
accessible Macro objects | |
2 | Recognition |
end event drop-down list | Selecting the value in the list |
Selecting the macro, on which the |
Closed – recognition of carriage license plates will start on the Sensor closed event
Open – recognition of carriage license plates will start on the Sensor opened event
LP recognition will be completed and the result will be given | List of accessible Macro objects | <none> | Depending on number of accessible Macro objects |
3 | Operation |
mode drop-down list | Selecting the value in the list |
Selecting operation mode used for recognition of |
numbers | List of |
accessible operation modes | Recognizer of railway passenger carriage numbers | Recognizer of railway passenger carriage numbers – is used for recognition of railway passenger carriage numbers Recognizer of railway freight carriage numbers – is used for recognition of railway freight carriage numbers Special mode – allows recognition of UIC carriage numbers Railway container number recognizer - is used for recognition of railway container numbers | ||||
4 | Fluid level detection drop-down list | Selecting the value in the list | Selecting the Fluid level detection object to use with the IntLab module. For details on this detection tool, refer to Detector Pack. User Guide (the most relevant version is available in AxxonSoft documentation repository). | List of accessible Fluid level detection objects | <none> | Depending on number of created Fluid level detection objects |