Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Open the intellect.ddi file in the ddi.exe utility.
  2. Select the CAM object.
    Image Modified
  3. Go to the Events tab.
  4. Set the Do not record and Do not send to the network checkboxes checked for the MD_START (Alarm) and MD_STOP (Alarm end) events.
  5. Save the file.

  6. Update the database using the idb.exe utility (the Update database button, see Interface elements of the idb.exe window).

...

In order the intellect.ddi file is not substituted it is to be saved with another name at step 5 - e.g. "intellect_1.ddi". Thus, 2 files of external settings are saved in the Languages catalog: source file and modified one. The idb.exe utility loads them in alphabetical order. As a result the intellect_1.ddi file is loaded the last one and its parameters are applied when database is updated.

If the event list in intellect_1.ddi is different from the original intellect.ddi, e.g. some events are added or deleted, then the event list is merged by idb.exe DB update.

When installing a new Intellect version the intellect_1.ddi file is not affected by the installation wizard and changes are saved.

...