Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Enable the Intellect debug mode (see Selecting Enabling and enabling configuring the debug mode of Intellect software).
  2. Set the 1 value for the Debug parameter (see see Registry keys reference guide, for information about working with the registry, see see Working with Windows OS registry).

    Info
    titleNote

    If there is no Debug parameter, it is necessary to create it.


  3. Restart Intellect to apply the settings.

To add the OPC server elements in debug mode, do the following:

  1. Double left-click the ITV OPC wrapper module icon in the Windows notification tray.
  2. In the window that opens, click the Service button (1).
  3. In the window that opens, expand the tree of elements by left-clicking the OPC server and the device (2).
  4. Set the checkboxes for the required OPC server elements (2).

    Info
    titleNote

    You can set the checkbox for the OPC server or for the device. In the first case, all elements of all OPC server devices will be checked, in the second case, all elements of the selected devices will be checked.


  5. Click Proceed (3).

  6. In the window that opens, set the checkboxes for the OPC server elements that should be added to the equipment tree (4).

  7. The following settings can be applied to the selected OPC server elements:

    1. If it is necessary to monitor the OPC server elements status, set the Monitoring checkbox (5).

      Info
      titleNote

      You can activate the monitoring of the OPC server element states later (see Configure the monitoring of OPC-server elements).


    2. If it is necessary to assign the Data Access rules for the OPC-server elements, select the corresponding rule in the Rule drop-down list (6) (see Configure rules for OPC-server elements of Data Access standard).
    Info
    titleNote

    You can select several OPC server elements at once using the hotkeys, for example:

    "Ctrl" + "a" — selecting all elements.

    "Shift" + left-click on the specified element — selecting all elements starting from the currently selected one to the one specified with the mouse click.

    "Shift" + keyboard arrows "down" or "up" — selecting the elements one by one going up or down from the currently selected one.


  8. Click Apply (7) to add the OPC server elements to the equipment tree.

...