Unable to render embedded object: File (books.jpg) not found.
Go to documentation repository
Page History
...
Section | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
New Features and Improvements
- New GUI for the ATM Intellect Operator's Workstation is introduced including:
- ATM Monitoring
- Recorded footage search (Archive Search)
- ATM Monitoring Reports
- The standard ATM events captioning function of the ATM Intellect Pro now uses REC_ROLLBACK command to initiate recording instead of REC.
- The ATM Events Interceptor module now supports automatic cash input devices. The module intercepts the following cash input device related events:
- Cash transaction. Cash transaction selected by a customer. Bill acceptor latch opened.
- Cash input complete. Bills inserted into the bill acceptor. Bills deposited.
- The amount is listed on screen. Unrecognized bills returned.
- Cancellation: bills deposited. The client aborted the transaction. All bills returned.
- The client has taken the money. The client has taken the money from the cash input device.
- The ATM has taken the money. The client has forgot to take the money from the cash input device. The ATM has retracted the money after a time-out period.
- The vault door opens.
- The vault door closes.
- Gateway mode added for Live Video display. After the successful installation of the ATM Intellect Operator's Workstation software you can use the Hardware tab to create a Data Gateway object. The Data Gateway is used for streaming video from the ATM Intellect Pro server to Additional Workstations belonging to other subnet(s) in an installation where the Intellect PSIM components are not comprising a distributed system, since the Video Gateway cannot be applied for this purpose.
- The 64-bit version of the Intellect kernel is now supported.
- External databases are now supported by the ATM Intellect Operator's Workstation. When installing the ATM Intellect Operator's Workstation software, you can set a remote SQL server on the monitoring database creation page.
- An option has been added to automate the loading of video files via the Search in Video Footage (GUI: Archive Search) module. An external system can now communicate with the Search in Video Footage module by means of .xml files via the designated exchange folders.
- A special operating mode for FSA and ACS modules has been introduced. Using the ATM Intellect Operator's Workstation, you can now create new users and set their access rights to each ATM Intellect Pro server. The list of user credentials is automatically transferred to each ATM-Intellect Pro server. This allows you such options as card-based access to ATM Intellect Pro enabled sites. The special operating mode is applicable where separate Intellect PSIM components cannot be joined into a distributed video surveillance system.
- The ATM Monitoring interface object has now its Control and Log panels synchronized.
- An object being selected via the Control panel becomes selected in the Log panel.
- The object's right-click context menu is now accessible from both Control and Log panels.
- The object filters on both panels are now synchronized.
- New filters have been added in the Control and History panels:
- Alarms. Displays only the objects currently containing short-term alarms not accepted by the operator.
- Failures. Displays only the objects currently containing unsolved long-term errors.
- Connected. Displays only the objects currently connected.
- Disconnected. Displays only the objects currently disconnected.
- You can have additional information about the object displayed:
- Hard drives' operating temperature
- IP address.
- Available amount of RAM.
- Continuous running time of the Intellect PSIM kernel.
- CPU load.
- The time of the earliest entry in Video Footage.
- Alternative algorithm added for generating Insufficient Video Footage Capacity alarms. This algorithm handles the cumulative Video Footage file size for a given number of days rather than for the total elapsed time.
- You can now access additional information on each camera's Video Footage via the Video Footage Details window.
- Time period, days Retention time for a single camera's Video Footage.
- Current, days. The size of the currently monitored portion of Video Footage specified in the Monitor Past Footage (days) setting of the ATM Intellect Pro.
- Total time, days Total cumulative size of Video Footage.
- Time period, days The currently monitored portion of Video Footage.
- Occupancy, %. The parameter indicates the integrity of Video Footage.
- First entry. The date of the earliest entry in Video Footage.
- Last entry. The date of the most recent entry in Video Footage.
- FIFO. Indicates that camera videos are recorded cyclically (First In First Out).
- Alarm. Indicates insufficient storage capacity for Video Footage.
- Added reference guides to: Oblast, District, City.
- Improved ATM Monitoring Reports interface object:
- You can now choose a type of report in object's settings.
- While building a report, you can now use filtering by oblast, district, city, failure category, alarm category and alarm notification content.
- Export added to .csv file.
- Set .xls as the default file format for exporting reports.
- While working with reports, the user's navigation over the list of video files is now enhanced with thumbnail display.
- Short term alarms' time stamp on an ATM Intellect Operator's Workstation can now be set in accordance with the ATM Intellect Pro system time.
- Improved Live Video Viewer module:
- The Alarm Response window now offers dedicated buttons to accept all alarms for a currently selected object or all alarms systemwide.
- The Video Data window now offers dedicated buttons to mark all loaded videos as viewed for a currently selected object or systemwide.
- You can now manage an ATM Monitoring object via scripts:
- The Log panel now includes the indication of maximum single disk free space across all logical drives available for Video Footage recording.
Bug Fixes
- Improved Archive Search interface object. The video request dialog now includes "Export to AVI" parameter. This parameter allows to select video format and codec for the exported video:
- Not Used: video is exported as an archive containing directories and files from the VIDEO folder.
- Source Format: video is exported into .AVI file without being transcoded.
- Xvid: video is exported into Xvid-coded .AVI file.
- DivX: video is exported into DivX-coded .AVI file.
- X264: video is exported into X264-coded .AVI file.
In ATM Intellect Pro, re-coded video is exported using the AviExport.run module. You have to install AviExport.run module version 4.10.5.3776 or higher, and the codecs you plan to use for exporting videos. In ATM Intellect Pro versions lower than 11.0.1520, "Export to AVI" parameter is forced to "Not Used" value.
- A dedicated "Export to AVI" setting is introduced to attach short videos to alarm events.
- Additional workplace configuration tool now includes "AVI-files Player" setting.
- To establish failover, you can now backup all data transferred from ATM Intellect Pro to the ATM Intellect backup workstation.
- The ATM Events Interceptor module is now capable to capture the client's payment card number from the ATM's event log (via ARTRA Advance NDC software), instead of requiring its insertion in a card reader.
- Improved ATM Monitoring Reports interface object. You can now set "Show Comment" parameter for System Failures and Alarms report types. Check this option to display the comment entered by operator into the "Reaction to Alarm" window during the alarm confirmation.
- Introduced new ordering of events in "Reaction to Alarm" and "Event Log" windows. By default, events are now ordered by time of occurring: newer events are displayed at the top of the list.
- Improved Archive Search interface object. The Object Selection window now includes "Fast Search" area where you can enter an ID or name of an object of interest.
- In the context menu, now you can choose to play live and recorded video from sites and facilities. To bring on screen all camera videos from the specified site or facility, select All Cameras of Surveillance Object from the context menu. Out of all cameras created in ATM Intellect Pro, only cameras specified in surveillance object settings will be displayed.
- You can now restrict operator's access to camera menu positions, CamMonitor buttons and HID controls.
- Log Panel can now be displayed in a light color scheme.
- Added an option to set a path to a folder where videos are exported to from the live/recorded footage viewing tile.
- For an ATM Monitoring interface object, you can now set "Video Stream Speed, FPS" parameter not only for live video but also for recorded footage. This requires CamMonitor component's version no less than 4.11.0.1766.
- Added a new object visualization mode in Control Panel and Owners Panel. If the time since last DB update exceeds 30 minutes, all objects in Control Panel and Owners Panel become diagonally hatched. This is a visual indication of a potential issue with database updates.
Bug Fixes
- Fixed an issue of non-displaying the number of cameras for an object in the Log Panel. This issue occurred if the video export path was set to a disconnected network disk.
- Fixed an issue with resuming video downloads.
- Fixed a bug that led to incorrect download status display in "Search in Archive" interface object.
- Fixed a bug that caused jittering of the Log Panel while scrolling horizontally with less than 8 columns visible.
- Fixed a bug that prevented changed IP address of ATM Intellect Pro from being recorded into the database at the ATM Intellect Operator's Workstation
- Now the Video Retrieval (GUI: Search in Archive) module allows you to load still frames or videos with identical time stamps from multiple cameras.
- The ATM Intellect Pro software version is now correctly displayed in the Log Panel.
- A number of minor bugs fixed.
- Some fixes and improvements in the documentation.
Overview