Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

To monitor the object status on the Agent Of Control side, create an AccessByCardEnable string registry key and set 1 as its value (for details, see Registry keys reference guide, for more information about working with the registry, see Working with Windows OS registry).

By default, the following alarms will become available in the Detection Tools alarm group:

Alarm groupEvent nameAlarm type (default alarm description)Alarm length
Detection Tools-Object disarmedLong alarm
OBJ_DISARMAttention! Service personnel are working!Short alarm
OBJ_ARMArmed objectShort alarm

These alarms are designed for the special mode of Monitoring operation with ACFA Intellect (see Configuring the special mode of Monitoring operation with ACFA Intellect). However, these alarms can be used to monitor the state of the relay, for example, to generate a short and long alarm when the relay switches from the Relay on to the Relay off state, and another short alarm when the relay switches from the Relay off to the Relay on state.

...

You can change the description of alarms for the OBJ_ARM and OBJ_DISARM events, and the long alarm Object disarmed (for details, see Changing the description of short alarms and a long -term alarm. The object is alarm Object disarmed).

To receive the short alarms Attention! The service staff works! it is necessary to set up an alarm group as shown below.

...

  1. In the System Settings dialog box, go to the Programming tab (1).
    Image Modified
  2. Create the Script object (2on the basis of the Scripts object in the object tree.
  3. If you are configuring the special mode of Monitoring operation with ACFA Intellect, it is necessary to copy the contents of a sample script from the page Sample scripts for determining the current state of the zones of the Rovalant (A6, A16) object on the Agent of Control side.
  4. If you are configuring the monitoring of the relay state, it is necessary to copy the contents of a sample script from the page на странице Пример скрипта для определения текущего состояния реле на стороне Агента КонтроляSample scripts for determining the current state of the relay on the Agent of Control side.
  5. Click Apply (3).

Operating procedure

At startup, and then every 15 minutes, Agent Of Control sends a GET_OBJECT_STATE event to the Intellect core. This event is processed in a script, which then generates an OBJECT_STATE_INFO event with the object status in the state field and the additional information in the card field. When the state of the relay changes, this script generates the OBJ_ARM or OBJ_DISARM event a long alarm Object disarmed.

Configuring alarms for monitoring the object state on the Agent Of Control side is complete.