Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

To change the description of a long alarm Object disarmed in the Monitoring and Monitoring Reports interface objects, it is necessary to specify the required description for the CustomizedLongAlarmName registry key on the Server Of Control and Central Server Of Control side (for details, see Registry keys reference guide, for more information about working with the registry, see Working with Windows OS registry).

To change the description of short alarms that occur with the OBJ_ARM and OBJ_DISARM events, do the following:

  1. Run the ddi.exe utility on the Agent Of Control side.

    Info
    titleNote
    For detailed information about working with this utility, see Intellect Software Integration Guide integration guide (HTTP API, IIDK, ActiveX, HTTP Server, Axxon Next).


  2. Open the intellect.atm.ddi file, which is located in the <Intellect installation directory>\Languages\ru.
  3. Select the VIDEOSRV_С object (1).
  4. Go to the Events tab (2).
  5. In the Description column, specify the necessary text for the OBJ_ARM and OBJ_DISARM events (3).
  6. Save the changes to the file and restart the Monitoring.
  7. In the same way, select the VIDEOSRV_S_DVC object (1) on the Server Of Control side.
  8. Go to the Events tab (2).
  9. In the Description column, specify the necessary text for the OBJECT_ARM and OBJECT_DISARM events (3).
  10. Save the changes to the file and restart the Monitoring.

...