# | Parameter | Method for setting the parameter value | Description | Type | Default value | Value range | |||||||
1 | Identifier | AutomaticallyEnter the value in the field | Shows the identification number of the Surveillance object object in the system | Nonnegative integerLatin, Cyrillic letters and service characters | - | Depends on number of Surveillance object objects in the system- | |||||||
2 | ParameterName | Enter the value in the field | Shows the name of the Surveillance object object in the system | Latin, Cyrillic letters and service characters | Surveillance object | A line representing a sequence of any | symbols symbols (letters, digits, service | characters apart from > and < symbols), not case-sensitivecharacters excluding characters: underscore "_", backslash "\", angle brackets ">" and "<", single quote "'"). Number of symbols – from 1 to 60. | |||||
3 | ATM-Intellect Pro | Is selected in the list | Assigns the parent ATM-Intellect Pro object for the Surveillance object object | Names of Surveillance object objects registered in the system | Name of the parent ATM-Intellect Pro object | Depends on the number of the ATM-Intellect Pro objects in the system. | |||||||
4 | ID | Enter the value in the field | Sets the unique ID number of the ATM machine | Nonnegative integer | 386 | >=0Latin, Cyrillic letters and some characters | 386 | A line representing a sequence of any symbols (letters, digits, service characters excluding characters: space " ", underscore "_", backslash "\" and single quote "'"), not case-sensitive. Number of symbols – from 1 to 9. | |||||
5 | TCP port (UPS -SCS) | Enter the value in the field | Sets the port on which to "listen" for UPS messages | Nonnegative integer | 8888 | from 1 to 60000 | |||||||
6 | Transmitting... | Click the button | Opens a dialog box with settings for configuring the communication between ATM-Intellect Pro and ATM-Intellect Workstation | - | - | - | |||||||
7 | Printer... | Click the button | Opens a dialog box for configuration of ATM receipts captioning. | - | - | - | |||||||
8 | Cameras | Using the Cameras... button | Displays the list of cameras whose state and archives are monitored by ATM-Intellect Pro and operating with which shall be available from ATM-Intellect software interface. | - | - | - | |||||||
9 | Cameras... | Click the button | Opens a dialog box for adding cameras for monitoring their status | - | - | - | |||||||
10 | Sensors | Using the Add, Edit and Delete buttons | Displays IDs and types of sensors whose state is monitored by ATM-Intellect Pro and on whose triggering video data are sent to the ATM-Intellect Workstation. | - | - | - | 11 | temperature sensor set | Is set in a checkbox | Specifies if monitoring to ensure that temperatures do not deviate from an allowed range is performed using temperature sensors | Boolean | FalseTrue – temperature sensors set is in use False – temperature sensors set is not in use | |
12 | Add... | Click the button | Opens a dialog box for adding a sensor. In this dialog box one can also setup video data sending on the sensor triggering | - | - | - | |||||||
13 | Edit... | Click the button | Opens a dialog box for editing the sensor. This dialog box is similar to the one for adding a sensor | - | - | - | |||||||
14 | Delete | Click the button | Deletes sensor from the list | - | - | - | |||||||
Titles group | |||||||||||||
15 | Displaying time (sec.) | Is selected in the list | Sets duration of captions displaying on video image beginning at the moment of corresponding event appearing from the secured object (ATM) | Seconds | 10 | 5, 10, 15, 20, 30, 45, 60, 90, 120, 200 | 16|||||||
Date and time | Is set in a checkbox | Specifies if it is necessary to include event date and time into the captions | Boolean | True | True – date and time are included into the captions False – date and time are not included into the captions | 17||||||||
ATM number | Is set in a checkbox | Specifies if it is necessary to include into the captions the number of ATM from which the event came | Boolean | True | True – ATM number is included into the captions False – ATM number is not included into the captions | 18||||||||
Card status | Is set in a checkbox | Specifies if it is necessary to include data on card status into the captions | Boolean | True | True – card status is included into the captions False – card status is not included into the captions | ||||||||
19 | Amount | Is set in a checkbox | Specifies if it is necessary to include operation amount into the captions | Boolean | True | True – amount is included into the captions False – amount is not included into the captions | 20|||||||
Card number | Is set in a checkbox | Specifies if it is necessary to include card number into the captions | Boolean | True | True – ATM number is included into the captions False – ATM number is not included into the captions | 21||||||||
Mask | Is set in a checkbox | Specifies if it is necessary to apply mask to a card number when displaying in in the captions | Boolean | True | True – card number is masked False – card number is fully displayed | ||||||||
11 | Sensors | Using the Add, Edit and Delete buttons | Displays IDs and types of sensors whose state is monitored by ATM-Intellect Pro and on whose triggering video data are sent to the ATM-Intellect Workstation. | - | - | - | |||||||
12 | Add... | Click the button | Opens a dialog box for adding a sensor. In this dialog box one can also setup video data sending on the sensor triggering | - | - | - | |||||||
13 | Edit... | Click the button | Opens a dialog box for editing the sensor. This dialog box is similar to the one for adding a sensor | - | - | - | |||||||
14 | Delete | Click the button | Deletes sensor from the list | - | - | - |